Gage Bilt GB208-625A Orijinal Talimat Kılavuzu - Sayfa 8
Perçin Aletleri Gage Bilt GB208-625A için çevrimiçi göz atın veya pdf Orijinal Talimat Kılavuzu indirin. Gage Bilt GB208-625A 20 sayfaları.
WARNING:
Only qualified and trained operators shall install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
It is required that eye protection, hearing protection and safety boots be worn at all times while handling this
equipment.
WARNING:
The users or the user's employer must assess specific risks that could be present before each use based on
their application.
● Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of
any moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
●
Verify the air lines and/or hydraulic hoses are not a trip hazard.
●
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool
●
Verify that hydraulic hose fittings and couplings, air and electrical connections are secure before each use.
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Do not carry from hoses or use as a hammer.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply, where applicable, when tool is not in use to prevent accidental start-up.
WARNING:
Do not exceed the maximum relief-valve setting stated on the tool and manual.
WARNING:
Do not operate when recommended pressures are exceeded as it could cause severe personal injury and or
damage the equipment.
WARNING:
Use only Gage Bilt hydraulic hoses and couplings, or equivalent, rated for 10,000 psi. (689.48 bar) working pressure.
CAUTION:
Do not use beyond the design intent.
1. Set hydraulic power unit to the recommended pressure, 5,600 psi (386.1 bar) Max. for the pull and 2,400 psi (165.5 bar) Max. for the
return. Gage Bilt pressure gage assembly (942280) (Sold Separately) is recommended to aid in this procedure. "See hydraulic power
unit manual for correct procedure when adjusting pressures".
Note:
Power units require a free flow of air for cooling purposes and should therefore be positioned in a well ventilated area
free from hazardous fumes.
2. Turn off the hydraulic power unit. Wipe all couplers clean before connecting. Failure to do so can result in damage to the couplers
and cause overheating. Connect hydraulic hoses then electric cord to power supply.
3. Turn hydraulic power unit on and cycle tool five times by depressing actuator to ensure piston
is in the full forward position.
4. Disconnect electric cord / air line from power supply.
5. Attach nose assembly:
5a. Unscrew and remove socket head cap screw (206101)
and stop (206102) from cylinder assembly (208103).
5b. Screw nose assembly onto tool.
5c. Insert drawbar into nose assembly and thread into
piston assembly (208111) on tool.
5d. Insert hex key into front of draw bar and tighten.
(See proper nose assembly data sheet for further instructions).
5e. Insert socket head cap screw (206101) into stop (206102)
and reattach to cylinder assembly (208103).
6. Re-connect electric cord / air line into power supply.
GB208-625 / GB208-625A
HOW TO SET-UP THE GB208-625/ GB208-625A
MUST
read and understand all warnings and cautions.
5,600 psi
(386.1 bar)
. for
Max
the pull
2,400 psi
(165.5 bar)
Max. for
the return
S.H.C.S. (206101)
& STOP (206102)
8
Thread nose
to tool
Insert draw bar
into anvil
Tighten jam nut to drawbar
after inserting drawbar thru
anvil, collet and piston i.d.
.
9/16 REV 6/22