DESCRIPTION
The GB585 is a hydraulic installation tool capable of installing 5/8" and 3/4" Magna-Grip® or standard lockbolts. It weighs just un-
der 20 lbs. (9.07 kg) and is our most powerful hand tool. It has a 1.600" (40.6 mm) rivet setting stroke and a rated pull load of 40,000
lbs (177.9 kN).
The GB585 installation tool operates on hydraulic pressure powered by the GB940 powerunit, set at 5400-5700 psi (372-3 - 393.0
bar) PULL pressure and 2200-2400 psi (151.7- 165.5 bar) RETURN pressure. The tool comes equipped with 24" hoses complete with
quick disconnects.
NOSE ASSEMBLIES ARE NOT FURNISHED WITH THE RIVETER AND MUST BE ORDERED SEPARATELY.

MAINTENANCE

WARNING:
Excessive contact with hydraulic oil and lubricants should be avoided.
WARNING:
Maintenance personnel
WARNING:
Disconnect tool from its power source before performing maintenance.
WARNING:
Be sure powerunit is disconnected before cleaning or when replacing worn or damaged components. Severe
personal injury may occur if power source is not disconnected.
WARNING:
Read MSDS documents for all applicable materials.
The performance of any tool depends upon good maintenance practices. Following these minimal requirements for service and care
will extend the life of your tool.
*Only use a hydraulic power source equipped with relief valves and pressures set within specified limits.
*Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor.
*Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
*Proper care by operators is necessary in maintaining full productivity and reducing downtime.
*Check tool, all hoses and all couplings daily for damage or air/hydraulic leaks. Tighten or replace (if necessary).
(See hydraulic thread preparation pg.5)
HYDRAULIC THREAD PREPARATION
IMPORTANT:
Be sure to use thread sealant on all hydraulic fittings, Loctite® 30534 or similar Teflon® infused pipe dope is recom
mended.
CAUTION:
may enter the hydraulic system and cause malfunction or damage. Use 1 1/2 wraps of tape on each thread. Cut off
all loose tape ends. Tighten until fitting feels snug and then go 1/2 to a full turn past that point.
tightening can easily distort the threads.

TORQUE SPECIFICATIONS

Socket Head Cap Screw (400047) = 20 inch lbs.
Button Head Cap Screws (404128) = 40 inch lbs.
Socket Head Cap Screw (401218) = 20 inch lbs.
Ejector Gland (762007) = 25 ft. lbs (see note
MUST
read and understand all warnings and cautions.
Teflon tape is an excellent thread sealer, however, if it is not properly applied, pieces of Teflon
on page 6)
2
5
CAUTION:
Over