Dyna-Glo RA18LPDG Kullanıcı Kılavuzu - Sayfa 14

Isıtıcı Dyna-Glo RA18LPDG için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Dyna-Glo RA18LPDG 16 sayfaları. Propane construction heater
Ayrıca Dyna-Glo RA18LPDG için: Kullanıcı Kılavuzu (19 sayfalar)

Dyna-Glo RA18LPDG Kullanıcı Kılavuzu
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING (continued)
Problem
Gas odor even when control knob is
in OFF position.
Gas odor during combustion.
Heater shuts off on ODS.
Possible Cause
1. Gas leaks. Refer to front of page
Warnings.
2. Gas control defective.
1. Foreign matter in gas or on burner ports.
2. Heater burning vapors form paint,
impurities in air.
3. Gas leaks, refer to front page Warnings
1. Not enough fresh air is available.
2. Low gas pressure.
3. ODS pilot partially clogged.
1-877-475-5660
What To Do
1. Locate and correct leaks immediately.
2. Replace gas control
1. Check gas passage way and burner.
2. Ventilate room, stop storing and using
odor causing products near heater.
3. Locate and correct leaks immediately.
1. Open window.
2. Contact gas supplier.
3. Clean the pilot.
1-877-475-5660
14