Dyna-Glo RMC-55R7 Kullanıcı El Kitabı - Sayfa 17

Isıtıcı Dyna-Glo RMC-55R7 için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Dyna-Glo RMC-55R7 20 sayfaları. Portable kerosene heater
Ayrıca Dyna-Glo RMC-55R7 için: Kullanıcı El Kitabı (20 sayfalar)

Dyna-Glo RMC-55R7 Kullanıcı El Kitabı

TROUBLE SHOOTING GUIDE

TROUBLES
Heater Will Not Light ;
1. Fuel tank is empty
2. Water present in kerosene
3. Igniter plug Fails to Glow
4. Igniter plug makes contact with
side of wick
Heater Produces Smoke or Odor ;
1. Flame is too high
2. Heater is in an air draft
3. Burner is not level
4. Carbon or tar built up on wick
5. Contaminated kerosene
Flame Flickers or Dies ;
1. Water present in kerosene
2. Carbon or tar built up on wick
Wick Burning Down Excessively ;
1. Dangerous, volatile fuel
mixed with kerosene
(gasoline, benzene, alcohol,
white gas, paint thinner, camp,
stove fuel, oil compound)
Wick Adjuster Sticks ;
1. Water present in kerosene
2. Carbon or tar built up
Heater is enveloped in flames ;
CORRECTIVE ACTION
1. Fill tank with water-clear 1-K kerosene or
red dyed 1-K kerosene.
2. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
3. Replace batteries if necessary. Be sure batteries are installed
properly. Replace igniter plug. Check for broken or disconnected wire.
4. Lower wick using wick adjuster knob until igniter plug
makes contact with top of wick.
1. Using wick adjuster knob, lower wick to desired 1/2" flame.
2. Move heater out of air draft.
3. Using burner knob, rotate burner from side to side until it
seats properly over wick.
4. Perform "Carbon Removal / Dry Burning" procedure.
Replace wick if necessary.
5. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
1. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
2. Perform "Carbon Removal / Dry Burning" procedure.
Replace wick if necessary.
1. Drain and clean tank
Remove and replace wick
Fill tank with water-clear 1-K kerosene
or red dyed 1-K kerosene.
1. Drain tank. Remove wick assembly & replace wick.
Reinstall wick assembly. Fill tank with water-clear
1-K kerosene or red dyed 1-K kerosene.
2. Perform "Carbon Removal / Dry Burning" procedure.
Replace wick if necessary.
Call Fire Department.
Smother flames with fire extinguisher or sand. Otherwise
smother flames with blankets and then throw water on
blankets.Do not throw water directly on the heater itself.
16