Dawn 5036 Montaj ve Kullanım Kılavuzu - Sayfa 14

Çiftlik Ekipmanları Dawn 5036 için çevrimiçi göz atın veya pdf Montaj ve Kullanım Kılavuzu indirin. Dawn 5036 19 sayfaları.

REFLEX CENTER MANIFOLD ASSEMBLY (12.1)

PRESSURE
RETURN
RETURN
TO ROW UNITS
Select a location to install the center manifold, ideally
between the two center rows.
Plumb the pressure and return trunk lines to the
indicated ports.
Route your row-to-row hoses from the center manifold
directly to the actuators as shown in fig. xxx. Ensure
hoses do not get crossed during install. Marking the
pressure and return hoses before installation is
recommended for ease of identification.

TRUNK HOSES (12.2)

Route ½" hose down draft arms allowing enough hose
for all folding points. Cut hose to length and crimp
supplied fittings to manufacturer specifications.
HOSES SHOULD BE CRIMPED AT YOUR
IMPLEMENT DEALER WITH THE PROPER
DAWN does not accept liability for
©2018 Dawn Equipment Company, Inc. 370 N Cross Sycamore, IL 60178 USA
Hydraulic Components
91198 –
ADAPTER, -8 JIC
ELBOW
UPLIFT
PRESSURE
PARKER HOSE CRIMPER.
improperly crimped hoses.
SYSTEM OPERATING
PRESSURE GAUGE
91157 –
ADAPTER, -10
ORB -8 JIC
CLOSE VALVE TO OPERATE
REFLEX SYSTEM

ROW-TO-ROW HOSE ROUTING (12.3)

Starting for the center manifold, route hoses from the
corresponding RETURN, PRESSURE & UPLIFT
adapters to the row unit actuators. Continue along
toolbar to final rows.
Check clearance with seed tubes and vacuum lines to
prevent unnecessary wear. It is advisable to have
hydraulic hoses routed under any other tubes many
times. It may be necessary to alter the angle of the
adapters in the actuators to clear obstacles.
The first and final row actuators will require the
adapters to be replaced with supplied -8 ORB Hex
Hollow Plugs (PN 9533)

WING HOSES (12.3)

Route wing hoses from outer row units on center
section, around the folding point, to the first row unit
on wing, ensuring enough slack to fold and unfold
without being stretched or pinched. Many times, it is
helpful to do this routing with the toolbar half unfolded
to visualize the routing.
www.dawnequipment.com
20 MICRON FILTER
(REPLACE EVERY 3 YRS.)
UPLIFT OPERATING
PRESSURE GAUGE
91197 –
ADAPTER, -8 ORB
-8 ORFS 45 DEG
ADJUST VALVE TO UPLIFT
PRESSURE
NOTE: Pressure
and return routing
may be
interchanged if
necessary, but
ensure uniformity
throughout the
system. Valve
cables will need to
match hose
routing.
Toll Free: 800.554.0007
Fax:815.899.3663