6.3 Disconnecting/storage of Pump Operation
1. Once the operation/use of the pump has been completed. Open the High Pressure/pressure
release valve (6), close the air stop/control valve (5), pull up the Air regulator control knob and
unwind the knob (13) until 0 bar of air pressure is reading on the air pressure gauge (19) [7].
2. Switch the air supply from the mains off.
3. Turn the Air stop/control valve into the open position [2b].
4. Twist and turn the air regulator control knob (13) to build up air pressure. Just enough to be able to
release the trapped air pressure.
NOTE: You should be able to hear the air pressure being released.
5. Once the trapped air pressure is released, switch the air stop/control valve (5) into the closed
position [2a]. then fully turn (anticlockwise) the air regulator control knob (13) and push down on
the knob, to lock it in place.
6. Air supply hose is now ready to be discounted and the pump can now be safely put away and
stored.
7
Even with the air supply being switched off their will still be air pressure trapped
in the hose between the mains air supply and the pump.
CLICK!
Operating Instruction Manual:
OM-AHP-BTU-01
15
Serial Numbers:
FROM BQ 9522