FIELD REVERSIBLE FRONT & REAR DOORS
The front and rear doors are installed right hand hinge as standard
from the manufacturer. Removing the hinges allows you to reverse
the door by flipping them over and reinstalling the hinges using the
universal mounting holes. Begin both screws, then tighten while
maintaining perfect vertical alignment. See detail below. All cabinet
frames and doors have provisions to be hinged right or left hand. The
handle can be reversed along with the hinging. See Operating Handle.
HINGE MOUNTING
Reversible
Hinge (Female)
Flat Head
Phillips Screw
# 10-32 x 1/2

SIDE PANEL REMOVAL

The side panels are secured to the cabinet frame with two quick
release latches and a keyed lock. Be sure to unlock the side panel.
To remove the side panel, squeeze the quick release latches towards
each other. Then tilt the top of the side panel out slightly and lift the
side panel up a couple of inches until it is free. To install the side panel,
reverse the process. Make sure the slots on the side panel engage with
the two tabs at the bottom of the frame.
SIDE PANEL REMOVAL
Keyed Lock
Slam
Latch
6
DOOR DETAIL
Tilt
Pivot Washer
Reversible
Hinge (Male)
Flat Head
Phillips Screw
# 10-32 x 1/2
FRAME DETAIL
Lift