Gaggenau VG 295 Kullanım Kılavuzu - Sayfa 13
Setüstü Ocak Gaggenau VG 295 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Gaggenau VG 295 16 sayfaları.
Trouble shooting
Malfunctions often have simple explanations. Please
read the following notes before calling the after-sales
service.
Fault
Burner does not ignite when
switched on, operation indica-
tors are off.
Burner does not ignite when
switched on, operation indicator
of the switched on burner is flash-
ing.
Burner goes off during operation,
operation indicators go off, only
the operation indicator of the
affected burner continues to
flash for a few seconds.
Burners go off during operation,
operation indicators go off.
Burners go off during operation,
all operation indicators are flash-
ing.
The kitchen smells of gas.
Possible cause
No electrical power.
Malfunction of the burner or the gas
supply.
Malfunction of the burner or the gas
supply.
Power cut
Overheating protection
There may be a leak in the gas cylin-
der coupling.
Solution
Turn control knob to 0. Check the fuse box if the
fuse has tripped.
Turn control knob to 0.
Check:
▯
Are all burner parts correctly assembled?
▯
Is the gas shut-off valve open?
▯
Is the burner dry and clean?
▯
Is there an air pocket in the gas supply line after
first installation or changing the LP (propane)
gas tank?
▯
LP (propane) gas: is the gas tank empty?
Turn all control knobs to 0.
has cooled!
Check affected burner:
▯
Are all burner parts correctly assembled?
▯
Is the electrode soiled (food remains) or wet?
▯
Is the burner soiled by boiled over food?
▯
Check for strong draughts (for example open
window behind the cooktop)?
▯
LP (propane) gas: is the gas tank empty?
Turn all control knobs to 0. Check the power supply.
There will be no automatic re-ignition after a power
cut.
Turn all control knobs to 0. Wait, until operation indi-
cators go off.
Check that the coupling is sound.
Wait, until the appliance
13