Hi-Line ConSEP100 Kullanım ve Bakım Kılavuzu - Sayfa 8

Su Filtrasyon Sistemleri Hi-Line ConSEP100 için çevrimiçi göz atın veya pdf Kullanım ve Bakım Kılavuzu indirin. Hi-Line ConSEP100 15 sayfaları. Oil / water separator

7. Insert connector for outlet (OT); then fit drain tube to connector.
8. Insert dedicated screw to close connection test.
3.4 ACTIVATION OF ConSEP 1500 AND REPLACEMENT FILTER KIT
Perform the following steps to correct installation.
ConSEP 1500
1. If present, remove only the plastic bag of activated carbon (CF) of both separator.
2. Put the activated carbon bag (CF) of both separator in a receptacle filled by clear water at least 8 h
before connecting the condensate drain.
3. Place foam (FM), as shown in photo, in the lid (LD) (activity #1); place activated carbon layer (CAF)
above the foam. Same operation in both lids.
8/15