Hi-Line DIN-DMX2-RJ45 Ayarlar Kılavuzu
Kontrolör Hi-Line DIN-DMX2-RJ45 için çevrimiçi göz atın veya pdf Ayarlar Kılavuzu indirin. Hi-Line DIN-DMX2-RJ45 2 sayfaları. Din rail 4channels dmx512 led controller
www.hiline‐lighting.co.uk T.020 3807 0525
DIN Rail 4Channels DMX512 LED Controller settings (DIN‐DMX2‐RJ45)
Using the digital display and respective buttons you may change "default settings" as shown below
1. Set the DMX512 start address
Pressing 1st & 2nd button for 2 seconds will activate "DMX set" process
Use the respective 3 buttons to set the DMX start address accordingly.
Press any button for 2 seconds to save the settings.
2. Select 3 or 4 channels operation (RGB/RGBW)
Pressing 2nd & and 3rd button for 2 seconds "cH" will appear at the display flashing (cH=channel
selection mode)
Using the 1st button you may choose 1/2/3/4 "cH" which will set the controller active channels.
As an example "3" will set 3 active channels out of 4 available.
Press any button for 2 seconds to save the settings.
(Default setting is "4" channels)
Notes:
Setting active channel to "1": All 4 channels to respond at the DMX address 001
Setting active channel to "2": Channels 1 & 3 will respond at the DMX address 001, Channels 2 & 4
will respond at the DMX address 002