DAYLIFF DG 5000P Kurulum ve Kullanım Kılavuzu - Sayfa 9

İnvertör DAYLIFF DG 5000P için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. DAYLIFF DG 5000P 12 sayfaları. Portable petrol generators
Ayrıca DAYLIFF DG 5000P için: Kurulum ve Kullanım Kılavuzu (12 sayfalar), Kurulum ve Kullanım Kılavuzu (12 sayfalar)

DAYLIFF DG 5000P Kurulum ve Kullanım Kılavuzu

7. TROUBLE SHOOTING

PROBLEM
Engine does
not start
Oil leakage
from muffler or
air cleaner
No Electrical
output
Low Electrical
output
POSSIBLE CAUSE
Carburettor is blocked
Spark plug is wet / dirty
Air cleaner dirty
Too much engine oil
Insufficient engine oil
No fuel
Battery flat (Electric start)
Engine has tipped over
Circuit breaker tripped
Low output voltage
Excessive electrical load
SOLUTION
Clean carburettor
Clean and adjust plug
Clean air cleaner
Reduce oil to suitable level
Oil sensor is activated. Add oil
(Oil sensor prevents engine
from running if oil level is low)
Check fuel cock open
Clean if fuel filter blocked
Charge/replace battery
Right engine oil to drain
Reduce generator load
Check for short circuit in load
Loose connection in output cable
Check engine speed
Reduce generator load
6