Dynabrade 64100 Kullanım Kılavuzu - Sayfa 6

Endüstriyel Ekipmanlar Dynabrade 64100 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Dynabrade 64100 8 sayfaları. 21" metalworking station

Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
OPERATION INSTRUCTIONS
1. Before operation starts, you must first make sure that the main tank
is at its proper water level in the "Power off" position. If water level is
low add water to the main tank or, operate your reservoir valve to the
fill position until desired level is reached as indicated on the label at
the front of the machine. Continue by then switching reservoir valve
to the "float" position.
2. Turn power switch on to start filtering action and begin work.
3. Check reservoir level every 8 hours and refill as necessary.
UPPER ACCESS PANEL
(Removal may be required to plug in accessory)
(3)
(4) ADJUSTING THE
FLOAT ARM MAY
BE REQUIRED TO
FINE TUNE WATER
TRANSFER FROM
RESERVOIR TO
MAIN TANK
LEVEL HIGH BEND DOWNWARD
LEVEL LOW BEND UPWARD
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
W E T D E B U R R I N G S TAT I O N : O P E R AT I O N
4. During operation, the float valve will transfer (Drip) water into the
main tank from the reservoir to make up for evaporation. Turn power
off after extended operation (Min 4 Hours) and re-check initial "Power
off" water level. If low, carefully bend the brass rod on the float
assembly to move float body up approximately 1/16". If "Power off"
water level is high, bend the brass rod on the float assembly to move
the float body down approximately 1/16". Re-check again after
extended operation.
(See set-up instructions for proper water level)
6

(2) POWER SWITCH

AUXILIARY
OUTLET 115V
ACCESSORY
CORD WRAP
(1) WATER LEVEL WINDOW