ADEMCO ADEMCO VISTA-20PSIA Programlama Kılavuzu - Sayfa 9
Güvenlik Sistemi ADEMCO ADEMCO VISTA-20PSIA için çevrimiçi göz atın veya pdf Programlama Kılavuzu indirin. ADEMCO ADEMCO VISTA-20PSIA 17 sayfaları. Ademco vista series security system
Ayrıca ADEMCO ADEMCO VISTA-20PSIA için: Hızlı Kurulum Kılavuzu (2 sayfalar), Kullanıcı Kılavuzu (20 sayfalar), Hızlı Kurulum Kılavuzu (2 sayfalar), Hızlı Kurulum Kılavuzu (2 sayfalar), Hızlı Kılavuz (2 sayfalar)
Wireless Key Programming Templates
This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user number (see
System Operation section, Assigning Attributes Command in the Installation Instructions).
TEMPLATE ?
Enter desired template number 1–6 (see chart below), then press [∗] to
continue.
To exit the Template screen, press [#]. The system returns to the *58 Menu
mode Summary Screen.
TEMPLATE SUMMARY
L
01
02
03 04
T
23
22
21 23
The selected template is displayed.
The top line represents loop numbers, the bottom line represents each
loop's zone type.
Press [∗] to accept template and continue.
PARTITION (VISTA-20P)
Enter the partition (1, 2, or 3-common) in which the key is to be active.
Press [∗] to continue.
Wireless Key Predefined Default Templates
For 5804
Loop
TEMPLATE 1
1
2
3
4
TEMPLATE 2
1
2
3
4
TEMPLATE 3
1
2
3
4
5800 Series Transmitter Input Loop Identification
All of the transmitters illustrated have one or more unique
factory assigned input (loop) ID numbers. Each of the inputs
requires its own programming zone (e.g., a 5804's four inputs
require four programming zones).
For information on any transmitter not shown, refer to the
instructions accompanying that transmitter for details regarding
loop numbers, etc.
UL NOTE:
The following transmitters are not intended for
use in UL installations: 5802MN, 5802MN2, 5804, 5804BD,
5814, 5816TEMP, 5819, 5819WHS & BRS, and 5850.
The 5827BD and 5800TM can be used in UL Listed
Residential Burglar installations.
*57 Function Key Programming
The Function Key Worksheet is on page 14.
PRESS KEY TO PGM
Press the desired function key to be programmed, A-D, then press [∗] to
continue.
When done, press 0 to exit this mode and return to data field mode.
NOTE: A key programmed as a function key is no longer available to be
used as an end-user macro key or panic key.
PARTITION
Enter the partition (1-3) in which this function key will be active.
KEY "A" FUNC
Enter the desired function for this key:
00 =
For the Function key selected, the function will be as follows (default):
If A selected = Zone 95 (emergency key, same as [1] [∗] pair)
If B selected = Zone 99 (emergency key, same as [∗] [#] pair)
If C selected = Zone 96 (emergency key, same as [3] [#] pair)
If D selected = Single-button paging
(press the [D] key from *58 Menu mode Summary Screen)
Function
Zone Type
No Response
23
Disarm
22
Arm Away
21
No Response
23
No Response
23
Disarm
22
Arm Away
21
Arm Stay
20
24-hour audible
7
Disarm
22
Arm Away
21
Arm Stay
20
(press ∗ ∗ ∗ ∗ 57 while in Data Programming mode)
(continued in next column)
ENTER START ZONE
The system displays the lowest zone number of the highest available
consecutive 4-zone group.
To start at a different zone number, enter the zone desired, and press [∗]. If
the system has four consecutive zones beginning with that zone, the zone
number is displayed. If not, the system will again display a suggested zone
that can be used.
If the required number of consecutive zones is not available at all, the
system will display "00".
Press [∗] to accept.
Continue to the INPUT S/N (serial number/loop number) and XMIT TO
CONFIRM prompts described earlier in the *56 Menu Mode section.
IMPORTANT: When confirmed, the key is not active for arming/disarming
until it is assigned to a user number (using the assigning attributes command,
attribute "4"). See System Operation section in Installation Instructions.
When done, the keypad beeps three times and the display returns to the
ENTER START ZONE prompt to let you enter the starting zone for the next
wireless key.
For 5804BD
Loop
TEMPLATE 4
1
2
3
4
TEMPLATE 5
1
2
3
4
TEMPLATE 6
1
2
3
4
LOOP 3
LOOP 4
YOU MUST
ENROLL
LOOP 2
THIS
BUTTON
LOOP 1
5 8 0 1
5802MN
ENROLL AS
ENROLL AS
"UR" OR "RF"
"UR" OR "RF"
LOOP 1
5808
ENROLL AS "RF"
LOOP 1
5816
5809
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 2
LOOP 2
(REED)
(REED)
LOOP 3
(TERMINALS)
LOOP 1
LOOP 3
(TERMINALS)
(TERMINALS)
5 8 1 9
ENROLL AS "RF"
KEY "A" FUNC
(continued)
01 =
Single-button paging (sends a 999-9999 message to pager)
02 =
Display time
03 =
Arm AWAY (reports as User 00 if closing reports are enabled)
04 =
Arm STAY (reports as User 00 if closing reports are enabled)
05 =
Arm NIGHT-STAY (reports as User 00 if closing reports enabled)
06 =
Step Arming (arms STAY, then NIGHT-STAY if enabled, then
AWAY)
07 =
Output Device Command (for device programmed as system
operation type 66 in *80 Menu Mode)
08 =
Communication Test (sends Contact ID code 601)
09 -12= Macro Keys 1-4 respectively (defined by [#] [6] [6] command)
NOTE: Macros 11-12 apply to VISTA-20P only
Press [∗] to continue; returns to key number prompt with the next function key letter
displayed.
– 9 –
Function
Zone Type
No Response
23
No Response
23
Arm Away
21
Disarm
22
No Response
23
Arm Stay
20
Arm Away
21
Disarm
22
24-hour audible
7
Arm Stay
20
Arm Away
21
Disarm
22
LOOP 3
LOOP 4
YOU MUST
O N
O F
LOOP 2
F
ENROLL
LOOP
THIS
LOOP 1
1
BUTTON
LOOP 3
5804
ENROLL AS "BR"
ENROLL AS "BR"
LOOP 2
LOOP 2
(REED)
(REED)
LOOP 1
LOOP 1
(TERMINALS)
ALTERNATE
(TERMINALS)
POSITION
FOR LOOP 2
5816MN
ENROLL AS "RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
(Green)
(Red)
(Yellow)
5819S (WHS & BRS)
5850 (GBD)
ENROLL AS "RF"
ENROLL AS "RF"
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
LOOP 1
SET
HOUSE
CODE
5 8 0 4 B D
LOOP 1
(PRIMARY)
LOOP 2
(AUX.
CENTER)
LOOP 3
(AUX.
RIGHT)
5817
ENROLL AS "RF"
LOOP
1
MOTION
5890
ENROLL AS
"RF" OR "RM"
V20P-006-V0