Installation
If the following instructions and safety
warnings are not complied with, this may
result in damage to the unit, serious personal
injury or death.
•
The Agribox may only be installed by a certified technician.
•
Always block off any traffic in the vicinity where the Agribox is
being installed before commencing with any work on the
installation.
•
Always turn off the power to the Agribox before opening the
cabinet or carrying out service or maintenance on the Agribox.
Ensure that the power supply is not turned on accidentally. To
do this, a lock can be mounted to the red/yellow coloured main
switch.
•
Keep the direct vicinity free from animals and any internal
transport whilst carrying out installation activities.
•
Only use electrically insulated tools!
Mounting the cabinet to the wall
1. Remove the cover by unscrewing the 4
screws on the front of the cabinet with a
1.6 x 9 mm screwdriver.
Connecting power
Disconnect the power supply before you connect the Agribox!
Ensure that the power supply cannot be switched on accidentally whilst connecting the unit!
3. Feed the cables/leads through the glands into the cabinet and connect these according to the circuit diagram - see pages 6-8.
A
TYPE: Agribox Small
A = power supply
B = Klemko twilight sensor
C = Armatures
Gland feed-throughs: diam. of leads min. 11 mm, max. 14 mm.
2. 2. Mount the cabinet to the wall with 4 screws, preferably in the corners. If the user
chooses to mount the unit by screwing to the base plate, the sealing caps [6] included in
the package must be used in order to ensure that the unit is water-tight.
B2
B
C
A
B1
TYPE: Agribox Medium
A = power supply
B1/2 = Klemko twilight sensor
C = Armatures Group 1
D = Armatures Group 2
•
Ensure that you do not confuse the phase, earth and
null connections when connecting - this may result in
life-threatening situations!
•
Ensure that the power supply and voltage corresponds
to the power supply and voltage required by the Agribox.
These are clearly indicated on the cabinet sticker.
•
When connecting up, consult the circuit diagram in this
manual and always ensure that you comply with the
legally applicable connecting requirements (e.g. NEN 1010
for the Netherlands).
.
The lighting plan shows the conditions that must be taken into
account when installing. These instructions must be fully complied
with in order to ensure uniformity and a proper light level.
Agrilight BV cannot be held liable for damage
andor injury resulting from improper mounting
and installation.
C
D
TYPE: Agribox X
A = power supply
B = Connecting lead Agribox Medium
C = Armature Group 1
D = Armature Group 2
[6]
[6]
[6]
[6]
A
B
C
D
3