2gig Technologies 2GIG-FT1-345 Kurulum Talimatları
Güvenlik Sensörleri 2gig Technologies 2GIG-FT1-345 için çevrimiçi göz atın veya pdf Kurulum Talimatları indirin. 2gig Technologies 2GIG-FT1-345 2 sayfaları. Flood and temperature detector
Ayrıca 2gig Technologies 2GIG-FT1-345 için: Manuel (2 sayfalar)
INSTR,INSTL,2GIG-FT1 TEMP FLOOD SENSOR - P/N: 10008993 A- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.5000" X 11.000" - TOL. +/- 0.125"- SCALE: 1-1 - PAGE 1 OF 2- FOLDING: FOLD 4X TO FINAL SIZE: 2.125" X 2.750"- FINISH WITH LOGO SHOWING
2GIG-FT1-345
FLOOD AND TEMPERATURE DETECTOR
INSTALLATION INSTRUCTIONS
The 2GIG-FT1-345 is a fully supervised, tamper protected one-way 345 MHz
sensor. It will monitor the ambient temperature and/or will detect a wet/dry fl ood
condi on. The sensor reports wet/dry condi ons and temperature to the panel.
Flood Conditions
Once the sensor probe detects the presence of water for three (3) minutes, the
integral transmi er will send a wet alarm transmission to the panel. The probe will
also send a restore (dry) report when the presence of liquid is no longer detected
by the fl ood probe for three (3) minutes. For fl ood repor ng the sensor requires
the installa on of the supplied external fl ood probe. The sensor is capable of
detec ng clean or dirty fresh water, salt water, or tap water.
Temperature Conditions
Heat:
1. If the temperature is more than 95° F (35°C) for fi ve (5) minutes, the sensor
will send a loop 2 transmission.
2. If the temperature is less than 95°F (35°C) for fi ve (5) minutes, the sensor will
send a loop 2 clear.
Cold:
1. If the temperature is less than 41°F (5°C) for fi ve (5) minutes, the sensor will
send a loop 3 transmission.
2. In the temperature is more than 41°F (5°C) for fi ve (5) minutes, the sensor
will send a loop 3 clear.
Contents
Verify that the package includes the following:
• 1—2GIG Flood/Temperature Sensor
• 1—Sensor Mounting Plate
• 1—3V Lithium Battery ( Panasonic CR15H270 uninstalled)
• 3—3/8" Phillips Screws
• 1—Double Stick Tape Strip
• 1—Probe Mounting Plate
Installation Tools Required
• Phillips Screwdriver
Figure 1.Temperature/Flood Sensor Contents
B
A
D
A Double S ck Tape Strip
B Sensor Moun ng Plate
C Probe Moun ng Plate
D 3V Lithium Ba ery
E Phillips Screws (3/8")
F Flood Probe Cord
G Flood Probe
H Transmi er with Integral Temperature Sensor
Installing and Replacing Battery
Open Sensor Case as show in Figures 2 and 3.
Install or replace ba ery.
G
F
C
H
E
PRINTER'S INSTRUCTIONS:
Figure 2. Opening Sensor Case
Grip the base of the sensor case. Place thumb on tab and push down un l sensor
case separates.
Figure 3. Separate Sensor Case
Figure 4. Installing New Ba ery
BATTERY
Installing a New Battery and System Programming
NOTE: Do not install ba ery un l panel is in Sensor Programming Mode.
1. Place panel in Sensor Programming mode
2. Insert ba ery
3. Close sensor
Replacement Battery Installation:
NOTE: If ba ery has been previously installed
1. Remove ba ery and dispose of (mee ng state regula ons)
2. Wait two (2) seconds
3. Replace ba ery
4. Close sensor
Installing/Mounting Flood/Temperature Sensor
The 2GIG-FT1-345 Flood and Temperature Sensor includes two methods of
installa on:
1. Double S ck Tape Installa on (See Figure 5).
2. Screw/Moun ng Plate Installa on (See Figure 6).
It is strongly recommended that the Flood/Temperature Sensor be mounted using
screws (provided) and Moun ng Plate (provided).
Figure 5. Double S ck Tape Moun ng Sensor Moun ng Plate
FLOOD/
TEMPERATURE
SENSOR
MOUNTING
PLATE
1. PUSH DOWN ON
THUMB TAB.
2. PULL BACK PLATE
OFF OF COVER
REMOVE SENSOR
COVER FROM
SENSOR BASE
TEMPERATURE/
FLOOD SENSOR
BASE
BATTERY REMOVAL
AND/OR INSTALLATION
APPLY DOUBLE STICK
WALL
TAPE TO BACK OF
MOUNTING PLATE
FIRST
PUSH
SENSOR
ONTO
MOUNTING
DOUBLE
PLATE
STICK
TABS
TAPE
THEN PUSH
STRIP
UP
Copyright ©2015 Nortek Security & Control LLC 1