5.5. Operating mode 5

Direct display triggering with brightness control.
Configuration data
Byte-No.
Characteristics
0
0x21
2
0x20
4
0x27
Output data
Byte-No.
Function
Panel parameter (see explanations 5.6)
0-1
Mode (see explanations 5.8)
2
1. Digit (left / display digit with the highest value)
3
2. Digit
4
3. Digit
5
4. Digit
6
5. Digit
7
6. Digit
8
7. Digit
9
8. Digit (right / display digit with the highest value)
10
With 6-digit displays, the 1st and 2nd digit may not be triggered (and so on). But all 8 digits
always need to be assigned!
Description
2 Bytes output data
1 Byte output data
8 Bytes output data
9
Function
Panel parameter (see explanations 5.6)
Mode (see explanations 5.8)
Direct display
5. Operating modes