AirCycler g2-k Kurulum Test Kılavuzu

Fan AirCycler g2-k için çevrimiçi göz atın veya pdf Kurulum Test Kılavuzu indirin. AirCycler g2-k 2 sayfaları.
Ayrıca AirCycler g2-k için: Kurulum ve Kullanım Kılavuzu (11 sayfalar), Eğitim Kılavuzu (20 sayfalar), Kurulum Test Kılavuzu (2 sayfalar)

AirCycler g2-k Kurulum Test Kılavuzu
Ventilation Products
Testing the AirCycler® g2-k completed installation is an easy
two step process:
STEP 1
Test the FanConnect
STEP 2
Test thermostat, damper and furnace connection and
operation
a. With the thermostat o , turn on the FanConnect
switch.
b. Con rm the exhaust fan is running.
®
c. The AirCycler
g2 display should show the
Exhaust fan is on and the OA damper is open.
d. Con rm the OA damper is open.
e. Turn o exhaust fan.
a. Make sure exhaust fan is o .
b. Turn thermostat FAN switch to ON.
®
c. Con rm AirCycler
damper open.
d. Con rm furnace fan is running.
e. Remover AirCycler
should shut o ..
f. DONE! Replace AirCycler
See reverse for troubleshooting tips and frequently asked questions
®
(tm)
connection & operation
STEP
1
STEP
2
g2 display show's FAN and OA
®
g2 from it's base. Furnace fan
®
g2 controller on it's base.
AirCycler® g2-k Installation Testing Guide
EXH - EXHAUST
FAN IS ON
VENTILATION COMPLETE
FAN ON FROM
THERMOSTAT
OA - FRESH AIR
DAMPER IS OPEN
PERCENTAGE OF
LCD DISPLAY
OA - FRESH AIR
DAMPER IS OPEN
PERCENTAGE OF
VENTILATION COMPLETE
LCD DISPLAY