DynaLock 2000 Series Manuel - Sayfa 3

Kilitler tarafından DynaLock 2000 Series için çevrimiçi göz atın veya pdf Manuel indirin. DynaLock 2000 Series 6 sayfaları. Electromagnetic lock
Ayrıca DynaLock 2000 Series için: Kurulum Talimatları Kılavuzu (12 sayfalar)

DynaLock 2000 Series Manuel
FIG. E
3000 / 2000 TD OPTION
(TIME DELAY)
ADD
JUMPER
TIME DELAY OPERATION
1.
2.
3.
4.
Notes:
1.
This lock may accept any one of 4 different input voltages and be furnished
with a combination of options. Refer to page 1 for option location and
pages 2 and 3, fi gure A thru E, for wiring instructions that apply to
your specifi c installation.
2.
For additional system wiring information, refer to the installation
documentation furnished with the external hardware and / or
peripheral devices (I.E. power supply, station controls, keypad, card
readers, etc.) supplied by DynaLock and / or others.
OPERATING VOLTAGES
12 OR 24 VAC / VDC
CURRENT CONSUMPTION, ALL MODELS
12 VAC / VDC - 0.44 A
24 VAC / VDC - 0.22 A
PUT A JUMPER ACROSS TERMINALS 3 & 4.
MOMENTARILY OPENING THE CONTACT(S) AND
INTERRUPTING THE POWER ON 1 & 2 UNLOCKS THE DOOR.
THE DOOR WILL RELOCK AFTER THE DURATION OF THE TD.
SEE PAGE ONE FOR THE LOCATION OF THE TIMER
ADJUSTMENT CONTROL.
TIME ADJUSTMENT RANGE IS ONE (1) TO EIGHTY (80) SECONDS.

ELECTRICAL SPECIFICATIONS

12 / 24
VAC / VDC
INPUT
NORMALLY CLOSED STATION CONTROL(S),
I.E. PUSHBUTTONS, KEYSWITCHES, ETC.
WIRE MULTIPLE CONTROLS IN SERIES AS
SHOWN.
COIL RESISTANCE CHECK
1
REMOVE THE
2
MAGNET COIL
3
CONNECTOR
4
FROM THE
CIRCUIT BOARD TO
PERFORM THE COIL TEST
PROPER COIL RESISTANCE SHOULD BE
FROM POINTS 1 TO 3, ~ 53 OHMS
FROM POINTS 2 TO 4, ~ 53 OHMS
3