DynaLock 3000LC Series Manuel - Sayfa 5

Kilitler DynaLock 3000LC Series için çevrimiçi göz atın veya pdf Manuel indirin. DynaLock 3000LC Series 6 sayfaları. Electromagnetic lock
Ayrıca DynaLock 3000LC Series için: Kurulum Talimatları (4 sayfalar), Kurulum Talimatları Kılavuzu (12 sayfalar)

DynaLock 3000LC Series Manuel
DynaLock
705 Emmett Street Bristol, CT 06011-2728
Phone:(860)582-4761 Fax:(860)585-0338
DynaLock 3000 and 2000 Series electromagnetic locks equipped with the LP - Low Power Option are confi gured
to operate exclusively on 12V AC/DC input voltage. Current draw is 0.16 Amps for single models and 0.32 Amps
for double models.
Damage may occur if input voltage exceeds 16V AC/DC. Do not attempt operation at higher voltages.
GENERAL INFORMATION
BASIC INPUT POWER WIRING
3000/2000 x LP BASIC
FIG. A
NORMALLY CLOSED STATION
CONTROL(S), I.E. PUSHBUTTONS,
KEYSWITCHS, ETC.
WIRE MULTIPLE CONTROLS IN
SERIES AS SHOWN.
3000/2000 x LP BASIC
FIG. B
NORMALLY CLOSED STATION
CONTROL(S), I.E. PUSHBUTTONS,
KEYSWITCHS, ETC.
WIRE MULTIPLE CONTROLS IN
SERIES AS SHOWN.
3000/3000LC/2000 SERIES
LP - LOW POWER OPTION
SUPPLEMENTAL INSTRUCTIONS

12 VDC INPUT

(+)
12VDC
INPUT
(-)
12 VAC INPUT
12VAC
INPUT