Dynamax SAPIP-LTE Hızlı Başlangıç Kılavuzu - Sayfa 9
Veri Kaydediciler Dynamax SAPIP-LTE için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Dynamax SAPIP-LTE 10 sayfaları.
Skipping CFC
Due to an upcoming measurement cycle (in <90 seconds), the CPU is skipping the call to CheckForCommands
CheckforCommands...
The CPU is about to check the web server for new commands
00567,04/15/2019,15:30,12.2,+0.2206,+0.2222,+0.2225,+0.0083,+0.2229,+0.2228,+0.2229,+0.0087,00.0470,000
00,+30.3,5.07,0000,0000.0,T,F,KKKKKKKKKUK
Sample data record (number 567) to be sent for this unit with date, time, analog and digital readings
SENDING DATA
The CPU has initiated the SendData function
PUT /service/putData/TEST/sapDataGSM.XML HTTP/1.1
HTTP PUT request for SAPIP data
<idigi_data><sample><name>ZZ00890015.pComplete</name><value> ... </value></sample></idigi_data>
Sample data record ... encased within a Json string
Got M status = 15
the LTE network is disconnected
Got M status = 3
the cell tower is disconnected
Buffer overrun
the CPU was expcting a short message (like SMS) but got a long one (like a delayed data request). The
CPU has prevented the data from writing past the end of the buffer
RST LO
The CPU is resetting the LTE module
RST HI
The CPU has completed resetting the LTE module
FAST SAMPLE, NO SLEEP
The CPU will not put the LTE module to sleep becasue of the short measurement interval