15. SPECIFICATION:
3G Frequency (GSM fallback) GSM 850/900/1800/1900 Mhz
Outputs
Power supply
Power Consumption
Physical size
Antenna
Humidity
Operating Temperature
Operating Current

16. QUICK PROGRAMMING VIA SMS AND OPERATION

Program dial –to- open phone numbers (1150 numbers)
Note: Program dial to open phone numbers you NEED TO enter country code, and the complete number
as you would dial it.
*12*1234#71[country code]#72[relay][phone number]#72[relay][phone number]#72[relay][phone
number]#......
Relay= 1 or 2
Example:
Ireland Country code: 353 (UK: 44 / USA: 1) Do not use any leading zeroes.
086 5683624 (mobile number 1)
086 5682554 (mobile number 2)
086 2235644 (mobile number 3)
SMS format:
*12*1234#71353#7210865683624#7220865682554#7210862235644#
Operation
You can dial in or send SMS password code to the device to control relay.
*71*5678#:Trigger relay 1
*72*5678#:Hold relay1
*73*5678#:Release relay1
*74*5678#:Trigger relay 2
*75*5678#:Hold relay 2
*76*5678#:Release relay 2
3G Gate Opener
WCDMA:800, 850, 900, 1900 and 2100 MHz
2 outputs, NC/NO dry contact, 10A/240V AC / 24V DC
12~24V AC/ DC ( 12V DC/ 1.5A power supply adaptor included)
Standby: 42mA/hr / Relay on: 83 mA/hr
9.5 (L) X 6.0 (W) x 2.5 (H) cm
Short Antenna
Less than 80% RH
-20℃ to 50℃
Maximum 250mA, typically 55mA
Gainwise Technology Co., Ltd.