11.Trouble-Shooting

Before maintenance, please check following information.
Trouble details
Leakage
Noise
High hardness of
outlet water
Brine failure or
brine deficient
Brine tank water
overflow
No soft water after
regeneration
Backwash flow rate
too high or too low
Salty water
Drain port
continually drain
Cause
1.Connector-loose
2.O-ring broken
Air enters device
1.Unqualified raw water
2.Regeneration cycle too long
1.Inlet pressure too low
2.Brine pipe hindered
3.Injector broken
4.Brine pipe air leakage
1.Brine refill time too long
2.Remaining water too much
1.Controller broken
2.Low inlet pressure
3.No salt in brine tank
4.Injector hindered
5.Riser pipe o-ring broken
1.Without drain line flow control
2.Foreign material in flow
restrictor
1.Inlet pressure too low
2.Drain pipe or DLFC hindered
3.Excessive amount of saturated
salt solution in brine tank
4.Short time of fast rinse
1.Leakage happens in valve
2.Foreign material get stuck in
valve
1.Screw tight connector or reconnect
2.Replace o-ring
Re-backwash, empty air
1.Contact with supplier
2.Shorten regeneration cycle time
1.Increase inlet pressure,more than
0.15Mpa
2.Check and climinate the blockage
3.Replace injection
4.Check brine pipe components,eliminate
leakage
1.Shorten brine refill time
2.Check brine status
1.Replace the controller
2.Increase inlet pressure
3.Add salt and manual regenerate
4.Disassemble injector then clean,
assemble it
5.Replase o-ring
1.Install drain line flow control
2.Clean off foreign material
1.Install pressure pump
2.Eliminate block
3.Decrease amount of refill water
4.Extend fast rinse time
1.Replace valve
2.Clean off foreign material
9
Solution