Operation Check
Please check the operation flow chart below.
Operation
Status
Power OFF
LED display
N.O.
OPEN
Relay
output
N.C.
CLOSE
Troubleshooting
Malfunction
Cause
Power voltage
It does not work.
Cable disconnection, incorrect connection
Rated sensing distance
Sometimes
Pollution by pollutant on the lens of Emitter Receiver.
it does not work.
Rated sensing distance
It is operated even if
There are obstacles between Emitter and Receiver.
people does not enter
in sensing area.
There is equipment generating strong noise or ratio
wave (Motor, Generator, High-tension wire).
Cautions during Use
1. Follow instructions in 'Cautions during Use'.
Otherwise, It may cause unexpected accidents.
2. 12-24VDC, 12-24VAC power supply should be insulated and limited voltage/current or Class 2, SELV power supply
device.
3. Use the product, 1 sec after supplying power.
When using separate power supply for the sensor and load, supply power to sensor first.
4. When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between
0V and F.G. terminal to remove noise.
5. When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
6. Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
7. This unit may be used in the following environments.
①Indoors (in the environment condition rated in 'Specifications')
②Altitude max. 2,000m
③Pollution degree 3
④Installation category II
• Normal operation
• No human or any material
between sensors
(red/green)
OPEN
CLOSE
Door Side Sensor
Human or material is passing
between sensors
(When cutting off the transmitted
beam)
CLOSE
OPEN
Troubleshooting
Check the power cable and adjust power voltage.
Please check wiring and terminal.
Use it in rated sensing distance.
Remove the pollutant.
Use it in rated sensing distance.
Remove obstacles.
Keep away from the equipment generating strong
noise or ratio wave.
: light ON, : light OFF
After human or material is passed
(red/green)
OPEN
CLOSE
C-15
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Connector Cables/
Sensor Distribution
Boxes/ Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software