TROUBLESHOOTING CHART
SYMPTOM
Brake does not release
1. Broken or damaged parts.
2. Wrong voltage.
3. Burned out coil.
4. Incorrect wiring connections or broken wires.
Brake does not stop
1. Broken or damaged parts.
properly
2. Worn friction disc.
3. Hub positioned incorrectly.
4. Brake is manually released.
Brake chatters or hums
1. Dirty magnet faces.
2. Magnet faces are not parallel in closed position.
3. Loose or broken shading coil.
4. Wrong voltage supply.
Manual release does not
1. Broken or damaged parts.
work
2. Improper setting.
ORDERING INFORMATION
Replacement parts can be purchased from your local distributor or from the Dings Co. To obtain the name
of your local distributor, call us or visit our website at www.dingsco.com.
For replacement parts, please furnish this data
with your order:
Brake model number
Part number and description (refer to parts list)
If ordering a hub, specify bore diameter and
keyway dimensions
If ordering electrical parts, specify voltage and
frequency
4740 W. ELECTRIC AVE.
MILWAUKEE, WI 53219
12
POSSIBLE CAUSE
414/672-7830
CORRECTIVE ACTION
1. Replace.
2. Check for correct voltage. Voltage must correspond to that listed on
brake nameplate. If the voltage is more than 10% below the
nameplate voltage, the magnet may not pull in.
3. Replace magnet assembly.
4. Find the connection or wiring fault. Correct or repair as required.
1. Replace.
2. Replace disc if worn to 1/8" thickness. If disc replacement is not
required, adjust air gap. (Refer to "Wear Adjustment" section.)
3. Relocated hub and key, if required. (Refer to "Installation" section.)
4. Determine if manual release is in normal position.
1. To remove dirt, insert a clean sheet of paper between faces and
energize brake. Move paper around between faces to dislodge dirt,
then remove paper.
2. See "Pivot Stud Adjustment" section.
3. Replace magnet assembly.
4. Check for low voltage.
1. Replace.
2. See "Manual Release Adjustment" section.
For a replacement brake, please furnish this
data with your order:
Brake model number
Voltage and frequency
Hub bore and keyway dimensions
Mounting - horizontal or vertical. If vertical,
specify whether above or below motor. If
brake includes foot mounting bracket or
adapter, specify.
FAX 414/672-5354
www.dingsco.com