Autonics BS5 Series Ürün Kılavuzu - Sayfa 2
Aksesuarlar Autonics BS5 Series için çevrimiçi göz atın veya pdf Ürün Kılavuzu indirin. Autonics BS5 Series 4 sayfaları. Groove-depth 9 mm photomicro sensors
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specific model, follow the Autonics website.
BS
5
-
❶
❷
❶ Appearance+Connection
Cable type
K1
T1
Distance from the center of sensing
to mounting surface: 7.3 mm
L1
Y1
V1
TA1
Distance from the center of sensing
to mounting surface: 10 mm
F1
R1
❷ Indicator
M: Turns ON under the light received condition
R: Turns ON under the light interrupted condition
❸ Control output
No mark: NPN open collector output
P: PNP open collector output
Sold Separately
• Connector: CT-01 (connector type), CT-02 (cable type, length: 1 m)
Cautions for Installation
• Tighten the screw with tightening torque under 0.49 N m.
• In case of F and R type, as shown below, make sure that the bottom of the product
and the mounting surface are in direct contact with each other.
Correct
-
❸
Connector type
K2
T2
Distance from the center of sensing
to mounting surface: 7.3 mm
L2
Y2
V2
TA2
Distance from the center of sensing
to mounting surface: 10 mm
F2
R2
Wrong
Connections
■ Cable type
Brown
LOAD
Black
NPN
Max. 100 mA
Blue
White
Light ON
Dark ON
■ Connector type
• For LOAD connection, follow the cable type connection.
• Be sure to connect the unit using the dedicated connector (CT-01 or CT-02, sold
separately).
If it is soldered on the unit terminal pin directly not using the connector (CT-01),
it may cause product damage.
Pin Color
①
②
③
④
■ Selectable operation mode
Operation mode Connection
Light ON
(White) Control wire connects with (Brown) +V
Dark ON
(White) Control wire connects with (Blue) 0V or does NOT connect
Circuit
■ NPN open collector output
LOAD
Max. 100mA
OCP
SCP
Light ON
Dark ON
• OCP (over current protection), SCP (short circuit protection)
• If short-circuit the control output terminal or supply current over the rated
specification, normal control signal is not output due to the protection circuit.
Operation Timing Chart
Indicator turns ON under
Model
light received condition
Received
Received light
Interrupted
ON
Operation
indicator
OFF
Light
ON
ON
Transistor
output
OFF
ON
Operation
indicator
OFF
Dark
ON
ON
Transistor
output
OFF
Brown
Max. 100 mA
Black
PNP
LOAD
Blue
White
Light ON
Dark ON
Function
Brown +V
White
Control
Black
Output
Blue
0V
■ PNP open collector output
Max. 100mA
OCP
SCP
LOAD
Light ON
Dark ON
Indicator turns ON under
light interrupted condition
Received
Interrupted
ON
OFF
ON
OFF
ON
OFF
ON
OFF