Autonics KN-1000B Series Ürün Kılavuzu - Sayfa 4

Ölçüm Cihazları Autonics KN-1000B Series için çevrimiçi göz atın veya pdf Ürün Kılavuzu indirin. Autonics KN-1000B Series 6 sayfaları. Bar graphic temperature indicators

Autonics KN-1000B Series Ürün Kılavuzu
■ Program mode
Parameter
Display Default Setting range
Input
2-1
aMA1 Refer to 'Input Type and Using Range'. -
specification
IN-P
Temperature
2-2
?C ℃, ℉
unit
UNIT
2-3 Low limit input
L-RG
0)00
High limit
2-4
input
H-RG
2)00
2-5 Decimal point
)0 0.0, 0.00, 0.000, 0
dP
2-6 Low limit scale
00)0 -1,999 ≤ L-SC < H-SC ≤ 9,999
L-SC
2-7 High limit scale
H-SC
10)0
Input
2-8
correction
01)
IN-B
0000
Bar graph
2-9
display low
L-BS
00)0
limit scale
Bar graph
2-10
display high
H-BS
10)0
limit scale
Bar graph
2-11
display
fBAR F.BAR: Full bar, C.BAR: Center bar
BAR
method
4 mA
2-12
transmission
lOUT
00)0
output scale
20 mA
2-13
transmission
hOUT
10)0
output scale
Input and
transmission
2-14
output
ExI0
SP
extension
02)
AL1 alarm
2-15
operation
AT!A
□□□.■
AL-1
AL1 alarm
2-16
option
AL2 alarm
2-17
operation
AL2 alarm
AL-2
AT!A
2-18
option
AL3 alarm
2-19
operation
AL3 alarm
AL-3
AT@A
2-20
option
AL4 alarm
2-21
operation
AL4 alarm
AL-4
AT@A
2-22
option
Alarm output
2-23
001 001 to 999
hysteresis
A-HY
Input special
2-24
function
InSF
LIN
Input digital
2-25
filter
MAvF
04
Digital input
2-26
HOLD HOLD: Hold, ZERO: Zero-point
Terminal
DI-T
Digital input
2-27
key
DI-K
HOLD
Sensor break
2-28
alarm output
BURN
OFF
Comm.
2-29
address
ADRR
01
2-30 Comm. speed
BAUD
9600
2-31 Lock
LOC
OFF
01) When '2-24 input special function' parameter is set to 'TUF', the function corrects the atmospheric pressure input
value.
02) Extension is not allowed below 0 mA and 0 V. ±1 V and 10 V inputs cannot be set to 10P.
Condition
2-1 Input
specification:
Thermocouple,
RTD
Using range low limit ≤ L-RG ≤ using
range high limit - 10% of F.S.
L-RG + 10% of F.S. ≤ H-RG ≤ using
range high limit
2-1 Input
specification:
Analog
• When setting '2-24 Input special
function: TUF'
L-SC: -760.0, H-SC: 0 to 9,999
2-1 Input
-999 to 999,
specification:
L-SC < IN-B < H-SC
Thermocouple,
RTD
2-1 Input
-999 to 999,
specification:
L-SC ≤ L-RG≤ IN-B ≤ H-RG ≤ H-SC
Analog
• Input: Thermocouple, RTD
Input range low limit ≤ L-BS ≤ (H-
BS-1)
(L-BS+1) ≤ H-BS ≤ Input range high
-
limit
• Input: Analog
L-SC ≤ L-BS ≤ (H-SC-1)
(L-SC+1) ≤ H-BS ≤ H-SC
-
[Transmission output model]
• Input: Thermocouple, RTD:
Within input range
-
• Input: Analog
L-SC ≤ L.OUT ≤ 10% of F.S.
≤ H.OUT ≤ H-SC
[Transmission output model]
Setting
Transmission
Input range
2-1 Input
value
output range
specification:
0P
No extension
4 - 20 mA
Analog
5P
±5% extension 3.2 - 20.8 mA
10P
±10% extension 2.4 - 21.6 mA
[Alarm output model]
□□□
AT0: Off
-
AT1: Deviation high limit alarm
AT2: Deviation low limit alarm
SBA: Sensor break alarm
A: Standard alarm
B: Alarm latch
C: Standby
D: Alarm latch and
-
sequence
standby sequence
• Enter to option setting: Press [◀] key
in 2-15 AL-1 alarm operation.
[Alarm output model]
Same as 2-15/16 AL1 alarm operation/
-
option
[4 alarm output model]
Same as 2-15/16 AL1 alarm operation/
-
option
2-15/17/19/21
AL-1/2/3/4
alarm
operation: AT1,
AT2
2-1 Input
LIN: Linear, ROOT: Root, SQAR:
specification:
Square, TUF: Two unit function
Analog
01 (OFF) to 16
-
• It does not affect the display cycle.
* 2-16/18/20/22
AL1/2/3/4
adjustment, AL.RE*: Alarm reset
Alarm option:
*[Alarm output model]
B, D
[Transmission output model]
-
OFF: 4 mA, ON: 20 mA
[Communication output model]
-
01 to 99
[Communication output model]
-
9600, 4800, 2400, 1200 bps
OFF
LOC1: Program mode lock (check
only)
Monitoring mode unlock
-
LOC2: Checking and setting program
mode lock
Monitoring mode setting lock
(check only)

Communication Parameter Setting

■ RUN status group
Address
Parameter
Display Output range
Display value
300001 (0000)
- Display value
output
[2 alarm output model]: 0 to 3
[4 alarm output model]: 0 to 15
300002 (0001) Alarm output
-
■ Monitoring mode setting group
Address
Parameter
Display Setting range
302001 (07D0)
[Alarm output model]
AL1 ~ 4 alarm
AL1
to
Thermocouple, RTD input: Within input specification,
temperature
-
302004 (07D3)
Analog input: L-SC~ H-SC
AL4
302005 (07D4) High peak
hPEK -
302006 (07D5) Low peak
lPEK -
■ Program mode setting group
Address
Parameter
Display Setting range
Value Display
0
1
2
Input
3
301001 (03E8)
specification
4
IN-P
5
• The setting values in '( )' parenthesis can be set only in
Temperature
UNIT 0: ℃, 1: ℉
301002 (03E9)
unit
301003 (03EA) Low limit Input
Same as parameter setting range
L-RG
301004 (03EB) High limit Input
H-RG
dP 0: 0, 1: 0.0, 2: 0.00, 3: 0.000
301005 (03EC) Decimal point
301006 (03ED) Low limit scale
Same as parameter setting range
L-SC
301007 (03EE) High limit scale
H-SC
Bar graph
301008 (03EF)
display low limit
L-BS
scale
Same as parameter setting range
Bar graph
301009 (03F0)
display high
H-BS
limit scale
Bar graph
BAR 0: Full bar, 1: Center bar
301010 (03F1)
display method
4 mA
301011 (03F2)
transmission
lOUT
output scale
Same as parameter setting range
20 mA
301012 (03F3)
transmission
hOUT
output scale
Input and
transmission
ExIO 0: 0 %, 1: 5 %, 2: 10 %
301013 (03F4)
output
extension
1: Deviation high limit alarm ,
301014 (03F5)
AL 1 to 4
AL-1
to
2: Deviation low limit alarm,
alarm operation
-
3: Sensor break alarm, 4: Off
301017 (03F8)
AL-4
10: Standard alarm, 11: Alarm latch,
301018 (03F9)
12: Standby sequence, 13: Alarm
AL 1 to 4
AL-1
to
latch and standby sequence,
alarm option
-
301021 (03FC)
14: No alarm (not settable)
AL-4
Alarm output
A-HY Same as parameter setting range
301022 (03FD)
hysteresis
0: Linear, 1: Root, 2: Square,
Input special
301023 (03FE)
3: Two unit function
function
InSF
IN-B Same as parameter setting range
301024 (03FF) Input correction
Input digital
MAvF Same as parameter setting range
301025 (0400)
filter
Digital input
DI-T 0: Alarm reset, 1: Hold,
301026 (0401)
Terminal
2: Zero-point adjustment
301027 (0402) Digital input key
DI-K
Sensor break
BURN 0: 20 mA, 1: 4 mA
301028 (0403)
alarm output
ADDR Same as parameter setting range
301029 (0404) Comm. address
BAUD 0: 9600, 1: 4800, 2: 2400, 3: 1200
301030 (0405) Comm. speed
LOCK 0: OFF, 1: LOC1, 2: LOC2
301031 (0406) Lock
Alarm status
Output
value
Alarm 1
Alarm 2
Alarm 3
0
OFF
OFF
OFF
1
ON
OFF
OFF
2
OFF
ON
OFF
3
ON
ON
OFF
4
OFF
OFF
ON
5
ON
OFF
ON
6
OFF
ON
ON
7
ON
ON
ON
8
OFF
OFF
OFF
9
ON
OFF
OFF
10
OFF
ON
OFF
11
ON
ON
OFF
12
OFF
OFF
ON
13
ON
OFF
ON
14
OFF
ON
ON
15
ON
ON
ON
Condition
Value Display
Value Display
(6)
(12) TC-P
TcK1
TC-B
(7)
(13) Cu50
TcK2
TC-S
(8)
(14) Cu10
TC-N
TC-J
(9)
15
TC-E
TC-C
JPt1
(10) TC-L
16
DPt5
TC-T
(11) TC-U
17
DPt1
TC-R
'Input specification expansion' mode. Refer to 'Mode
Setting'.
Same as each
parameter setting
condition
Alarm 4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Value Display
18
aMA1
19
aMA2
20
aMV1
21
aMV2
22
A-V1
23
A-V2