1.3 Specifications

STANDARD OPERATING CHARACTERISTICS
Code: Incremental
Pulses per Revolution: 1024
Phasing Sense: A leads B for Counter-Clockwise
rotation (CCW) viewing encoder-mounted end
Quadrature Phasing: 90° ±22°
Symmetry: 180° ± 54°
Index: 180° to 2160°
ELECTRICAL
Input Voltage Requirement: 5-24V DC
Current Requirement: 50 mA
Output Signals:
5-17 V Line Driver, 150mA
Frequency Response: 0 - 120kHz Data & Index
Electrical Immunity: 2kV ESD, Reverse Polarity,
Short Circuit
Connector: 10 pin industrial duty latching, sealed
NEMA 4 &12, IP65 with gold pins
ELECTRICAL CONNECTIONS
Signal
Connector Pin
Common
B
A
Z
No Connection
Vcc (5-15 VDC)
B
A
Z
Shield
Specifications subject to change without notice
Patent Pending
+1.800.873.8731
©DYNAPAR
Page 6
NorthStar WIND 56 Instruction Manual
SAFE TEMPERATURE RANGE
Deg. C
135
1
2
130
3
4
125
5
6
120
7
8
115
9
10
110
105
100
702820-0001 Rev. C
MECHANICAL
Shaft Speed: 5,000 RPM
Mounting Configuration: 4.5" 56C face mount
for NEMA MG1 standards
Housing Material: Cast Aluminum
Acceleration Rate: 12,000 rpm/sec max
Shaft Length Required: 0.7" min
Allowable Shaft End-Play: ± 0.045"
Wheel Bore: 1-1/8" with keyway or 15/16"
Weight: 2.8 lbs (1.3 kg)
ENVIRONMENTAL
Operating Temperature Range:
Standard: -40°C to +130°C
See Table Below
Storage Temperature Range: -40°C to +130°C
Humidity: to 98% RH (non-condensing)
Shock (Sensor Module): 1 meter drop test,
30 G's Min
Vibration: 18 G's @ 5-2000 Hz spectrum
Safe Operating Area