Autonics CTS Series Ürün Kılavuzu - Sayfa 4

Zamanlayıcı Autonics CTS Series için çevrimiçi göz atın veya pdf Ürün Kılavuzu indirin. Autonics CTS Series 11 sayfaları. Programmable digital counters / timers
Ayrıca Autonics CTS Series için: Manuel (4 sayfalar), Manuel (4 sayfalar)

Autonics CTS Series Ürün Kılavuzu
Detach the Case
■ CTS, CTY
Select Input Logic
• For CTS, CTY, detach the case and proceed the settings. See the 'Detach the Case' .
• The position of internal switch varies depending on the each model.
• How to change the settings:
power OFF → change settings → power ON → press [RESET] key or input the RESET
signal (≥ 20 ms) to the external terminal.
■ CTS, CTY
NPN PNP
SW1
NPN
PNP

Mode Setting

[◀]
[MD] 3 sec
[MD] 5 sec
RUN
Function setting check mode
[▲] 1 sec
[RST] or
terminal input
[BA]
01)  Use [▲], [▼] key to check the parameter setting.
In 2-stage preset model, 1-stage preset value and 2-stage preset value are displayed each time when pressing
[MD] key. In timer, it is available for the output operation mode: OND, OND.1, OND.2.
02)  For CT6M-1P / 2P model only. Press [◀] key to set BATCH counter setting value.
Preset Value Change Mode
Even if the mode of preset value change, input operation and output control will continue.
The preset value could be set to 0 and the output of 0 preset value occurs.
• The preset value could not be set to 0 depending on the output operation mode.
(When setting to 0, the value of setting value display part flashes 3 times.)
• If no key is touched for 60 sec, the product will return to RUN mode without being restored.
• E.g.: To set 1-stage preset value = 180, 2-stage preset value = 200
1. Press [◀] key to enter preset value change mode. PS1 indicator turns ON and 1 digit of
preset value flashes.
2. Use [◀], [▲], [▼] key to set 1-stage preset value = 180.
3. Press [MD] key to enter 2-stage preset value change mode.
4. Use [◀], [▲], [▼] key to set 2-stage preset value = 200.
5. Press [MD] key to return RUN mode.
Reset
In RUN mode, if pressing [RST] key or
applying the signal to RESET terminal on the
back side, present value will be reset.
For RESET signal terminals based on the
input method, refer to the 'Connections' and
the following table.
The output maintains OFF state.
Error Display and Output Operation
• When error occurs, the output turns OFF.
• When setting 1-stage preset value = 0, OUT1
output turns OFF.
In case of 2-stage preset value < 1-stage
preset value, OUT1 output is ignored and
only OUT2 output operates.
• Indicator model does not have error display
function.
Find Quality Products Online at:
• Press to direction ① and pull toward
direction ② for detaching the case and
contents.
᜸ Caution: Turn OFF the power before
detaching the case.
■ CTM
SW1
Front
PNP
NPN
NPN
PNP
Preset value change mode
[MD]
Parameter 1 group
[MD] 3 sec
Parameter 2 group
[MD] 3 sec
[MD] 1 sec
01)
Reset
Auto
BATCH counter
[MD]
indication mode
02)
Input logic
Model
No-voltage (NPN) Voltage (PNP)
Short no. 9, 10
Short no. 8, 10
CTS
terminals
terminals
Short no. 4, 5
Short no. 3, 5
CTY
terminals
terminals
Short no. 11, 12
Short no. 10, 12
CTM
terminals
terminals
Display
Description
Troubleshooting
Change the preset
Preset value = 0
value anything but
ERR0
0.
GlobalTestSupply
www.

Parameter Setting

• Some parameters are activated / deactivated depending on the model or setting of other
parameters. Refer to the description of each parameter.
• If changing the setting value of parameter 1 group via communication, reset display
value, and output.
• [MD] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [▼] key: Changes setting values.
■ Parameter 1 group (counter)
Parameter
Mark
Counter /
C1-1
timer
01)
C-T
Input
C1-2
operation
IN
mode
01)
Output
C1-3
operation
OUtM
mode
01)
Indication
C1-4
mode
01)
DSpM
Max.
C1-5
counting
CPS
speed
01)
OUT2
C1-6
output
OUT2
time
01) 03)
OUT1
C1-7
output
OUT1
time
01) 03)
OUT
RUN
C1-8
output
OUtT
time
01) 03)
Counting
value /
C1-9
preset value
DP
decimal
point
01)
Min. RESET
C1-10
time
RST
C1-11 Input logic
SIG
Prescale
C1-12
decimal
ScDP
point
01) 05)
Prescale
C1-13
value
01)
SCL
Start Point
C1-14
value
01) 06)
STRT
Memorize
C1-15
counting
DATA
value
C1-16 Key lock
LOCK
01)  When the setting value of the parameter is changed, all outputs are OFF and reset the current value when
returning to the RUN mode.
02)  C1-3 Output operation mode: in case of D, 1, 30, 1k cps selectable.
C1-5 Max. counting speed: 5k, 10k cps & C1-3 Output operation mode: When D is set, the max. counting speed is
automatically changed to 30 cps.
03)  In case of 1-stage preset model, C1-7 OUT1 output time is not displayed, C1-6 OUT2 output time is displayed as
OUT.T.
04)  For other output operation modes, Hold is fixed.
05) It can not be set smaller than the digits of C1-9 Counting value / preset value decimal point.
06) The setting range is connected to the C1-9 Counting value / preset value decimal point.
Defaults
Setting range
COUN COUN: counter, TIME: timer
UD-C: phase different input ,
UP, UP-1, UP-2, DN, DN-1, DN-2,
UD-A: command input,
UD-C
UD-B: individual input
[Preset setting model]
F, N, C, R, K, P, Q, A, S*, T*, D*
F
[Indicator model]
HOLD, TOTAL
• HOLD
TOTAL
: You can set the PRESET value.
30, 1K, 5K, 10K, 1 cps
• Max. counting speed is when duty
ratio of INA or INB input signal is 1:1.
30
It is applied for INA, or INB input as
same.
[2-stage preset setting model]
0.01 to 99.99 sec, Hold
HOLD
[2-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
0)10
key once and Hold appears.
[1-stage preset setting model]
0.01 to 99.99 sec, Hold
HOLD
[6 digit model]
------, -----.-, ----.--, ---.---, --.----, -.-----
------
[4 digit model]
----, ---.-, --.--, -.---
----
20 1, 20 ms
NPN, PNP
• Set the same as settings of input
NPN
logic selection switch.
[6 digit model]
-.-----, -----.-, ----.--, ---.---, --.----
-.-----
[4 digit model]
-.---, ---.-, --.--.
-.---
[6 digit model]
0.00001 to 99999.9
!00000
[4 digit model]
0.001 to 999.9
!000
[6 digit model]
0.00000 to 999999
000000
[4 digit model]
0.000 to 9999
0000
CLR: Resets counting value when
power is off.
REC: Memorizes counting value at the
CLR
moment of power off.
(memory retention)
L.OFF: Unlock key LOCK,
key LOCK indicator OFF
LOC.1: Locks [RST] key,
key LOCK indicator ON
LOC.2: Locks [◀], [▼], [▲] key,
lOFF
key LOCK indicator ON
LOC.3: Locks [RST], [◀], [▼], [▲] key,
key LOCK indicator ON
.com
Display
condition
-
-
*C1-2 input
operation
mode: UD-A,
UD-B, UD-C
C1-2 input
operation
mode: UP,
UP-1, UP-2,
DN, DN-1,
DN-2
C1-3 output
operation
mode
02)
C1-3 output
operation
mode:
C, R,
K, P, Q, A
04)
C1-3 output
operation
mode:
F, N,
C, R, K, P, Q,
A
04)
C1-3 output
operation
mode:
C, R,
K, P, Q, A
04)
-
-
-
-
-
-
C1-2 input
operation
mode: UD-C,
UP, UP-1, UP-
2, UD-A, UD-B
-
-