Mode
Time chart and output operation description
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
Display
Setting time
Down
INT.1
(Interval 1)
OUT2 (OUT)
• Power reset
Control output turns ON and time starts when INA
input is ON.
When INA input is ON: Power on time start operates,
When reaching the setting time, Auto reset is activated.
Control output is ON when Time is progressing.
INA input is ignored while time is progressing.
POWER
INA (START)
INH (INHIBIT)
Setting time1
Setting time2
Up
Display
Setting time2
Down
Setting time1
INT.2
(Interval 2)
• Power reset
Time starts when INA input is ON. OUT1 is ON during T1
(hold) or t1 time.
RESET when INA input is OFF.
When reaching the setting time 1, the progressed time
is reset.
OUT2 is ON during T2 (hold) or t2 time.
• Output turns OFF when reaching the setting time
even if One-shot time is longer than the setting time.
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
Display
OFD
Setting time
Down
(Signal off
delay)
OUT2 (OUT)
• Power reset
If INA input is ON, control output remains ON.
(except when power is off and reset is on)
When INA input is OFF, time progresses. When reaching
the setting time, Auto reset is activated.
POWER
INA (START)
INH (INHIBIT)
RESET
On_delay
Up
Off_delay
Display
On_delay
Down
Off_delay
NFD
(On-Off
delay)
OUT2 (OUT)
• Power reset
1) When INA input is ON, output is ON and time is
progressing, then output is OFF after On_Delay time.
2) When INA input is OFF, output is ON and time is
progressing, then output is OFF after Off_Delay time.
If INA input is OFF within On_Delay time, step 2 starts
again.
If INA input is ON within Off_Delay time, step 1 starts
again.
Find Quality Products Online at:
0
0
POWER
INA
OUT2
Reset off time start operates.
(OUT)
T = setting time
RESET
0
0
OUT1
OUT2
INA
OUT1
OUT2
T1 = setting time 1
T2 = setting time 2
t1 = One-shot 1
t2 = One-shot 2
0
0
POWER
INA
OUT2
(OUT)
T = setting time
0
0
INA
OUT2
(OUT)
T1 = On_delay time
T2 = Off_delay time
GlobalTestSupply
www.
Mode
Time chart and output operation description
INH (INHIBIT)
Up
Display
NFD.1
Down
(On-Off
delay 1)
• Power reset
1) When INA input turns ON, time progresses and
T
output turns ON after On_Delay time.
2) When INA input turns OFF, time progresses and
output turns OFF after Off_Delay time.
If INA input turns OFF within On_Delay time, output
will turn ON and step2 operate.
If INA input turns ON within Off_Delay time, output
will turn OFF and step1 operate.
Up
INTG
Display
(Integration
time)
Down
• Power reset
Time is progressing during INA input is ON.
T1
Time stops during INA input is OFF.
Control output is ON when reaching the setting time.
T2
t1
■ Timer operation of indicator model
t2
Mode
Time chart and output operation description
• Memory retention parameter = CLR
Up
Display
Down
• Memory retention parameter = REC
TOTAL
T
Up
Display
Down
Time starts when INA input is ON.
Time is initialized when RESET input is ON.
Time stops during INHIBIT input is ON.
• Memory retention parameter = CLR
Up
Display
Down
T1
T2
• Memory retention parameter = REC
HOLD
Up
Display
Down
Time starts during INA input is ON.
Time stops during INA input is OFF.
When time reaches the setting time, time progress stops and is flashed.
When RESET input is ON, progressed time is initialized.
POWER
INA (START)
RESET
On_delay
Off_delay
0
On_delay
Off_delay
0
OUT2 (OUT)
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
0
Setting time
0
OUT2 (OUT)
POWER
INA (START)
INH (INHIBIT)
RESET
Time range
Max. display value
0
Time range
Max. display value
0
POWER
INA (START)
INH (INHIBIT)
RESET
Time range
Max. display value
0
Time range
Max. display value
0
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
0
Setting time
0
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
0
Setting time
0
.com
INA
T1
T2
OUT2
(OUT)
T1 = On_delay time
T2 = Off_delay time