Timer Operation
■ Output operation mode
Power reset: There is no memory retention.
Initialize the display value and output state when power on again.
Power hold: There is memory retention.
Memorize the display value at the moment of power off, restoring the memorized
display value and output state when power on gain.
• Output type
One-shot output
Retained (hold) output
One-shot output Retained (hold) output
Mode
Time chart and output operation description
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time 2
UP
Setting time 1
0
Display
Setting time 2
OND
Down
Setting time 1
(Signal on
0
delay)
OUT1
OUT2
• Power reset
Time starts when INA input is ON.
Time is RESET during INA input is OFF.
When INA input is ON: Power on time start operates,
Reset off time start operates.
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time 2
UP
Setting time 1
0
Display
Setting time 2
OND.1
Down
Setting time 1
(Signal on
0
delay 1)
OUT1
OUT2
• Power reset
Time starts when INA input is ON.
When INA input is ON: Power on time start operates,
Reset off time start operates.
Only the first signal is valid in case INA input signal is
repeatedly applied.
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time 2
UP
Setting time 1
0
Display
Setting time 2
Setting time 1
Down
OND.2
0
(Power on
OUT1
delay)
OUT2
• Power hold
Power on time start (no INA function)
Time is RESET when RESET is ON.
Time starts when RESET ON → OFF.
POWER
INA (START)
INH (INHIBIT)
RESET
setting time 2
UP
setting time 1
0
Display
setting time 2
OND.3
Down
setting time 1
(Power on
0
delay 3)
OUT1
OUT2
• Power hold / reset
Power on time start (no INA function)
Time is RESET when RESET is ON.
Time starts when RESET ON → OFF.
When the power is turned on, if the setting time is
reached, auto reset is performed.
INA
T1
OUT1
T2
OUT2 (OUT)
T1 = setting time 1
T2 = setting time 2
INA
T1
OUT1
T2
OUT2 (OUT)
T1 = setting time 1
T2 = setting time 2
t
a t-a
HOLD
POWER
T1
OUT1
T2
OUT2 (OUT)
T1 = setting time 1
T2 = setting time 2
t
a
HOLD
POWER
T
OUT2
(OUT)
Mode
Time chart and output operation description
POWER
INA (START)
INH (INHIBIT)
RESET
T.off setting time
UP
T.on setting time
0
Display
T.off setting time
Down
T.on setting time
FLK
0
(Flicker)
OUT2 (OUT)
• Power reset
Time starts when INA input is ON.
When INA input is ON: Power on time start operates,
Reset off time start operates.
Output turns OFF from INA input turn ON to T.off setting
time, turns ON for the T.on setting time repeatedly.
In case of using the contact output, min. setting time
must be set over 100 ms.
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
0
Display
Setting time
Down
0
OUT2 (OUT)
• Power reset, retained (hold) output
Time starts when INA input is ON.
When INA input is ON: Power on time start operates,
Reset off time start operates.
Only the first signal is valid in case INA input signal is
repeatedly applied.
In case of using the contact output, min. setting time
must be set over 100 ms.
FLK.1
(Flicker 1)
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
0
Display
Setting time
Down
0
OUT2 (OUT)
• Power reset, One-shot output
Time starts when INA input is ON.
When INA input is ON: Power on time start operates,
Reset off time start operates.
Only the first signal is valid in case INA input signal is
repeatedly applied.
In case of using the contact output, min. setting time
must be set over 100 ms.
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
0
Display
Setting time
Down
0
OUT2 (OUT)
• Power hold, retained (hold) output
Time starts when INA input is ON.
When INA input is ON: Power on time start operates,
Reset off time start operates.
Control output will be reversed when it reaches to
setting time. But, at the initial Start, OUT2 control
output is OFF.
FLK.2
n case of using the contact output, min. setting time
(Flicker 2)
must be set over 100 ms.
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
0
Display
Setting time
Down
0
OUT2 (OUT)
• Power hold, One-shot output
Time starts when INA input is ON.
When INA input is ON: Power on time start operates,
Reset off time start operates.
In case of using the contact output, min. setting time
must be set over 100 ms.
T.off
T.on
Ta
Tb
T.on
T.off
T.on
T.off
T.on
POWER
INA
OUT2 (OUT)
Ta + Tb = T.off
T.off, T.on must be
set individually
POWER
INA
T
OUT2
(OUT)
T = setting time
t
t
t
POWER
INA
T
OUT2
(OUT)
T = setting time
POWER
INA
T
OUT2
(OUT)
T = setting time
t
t
t
a t-a
POWER
INA
T
OUT2
(OUT)
T = setting time
T.off
T.off
T.on
T.off
T
T
T
T
T-c
c T
HOLD
t
T-c
c T
HOLD