DynaQuip WaterCopPRO Kullanım Kılavuzu & Kurulum Kılavuzu - Sayfa 4
Sıhhi Tesisat Ürünleri DynaQuip WaterCopPRO için çevrimiçi göz atın veya pdf Kullanım Kılavuzu & Kurulum Kılavuzu indirin. DynaQuip WaterCopPRO 8 sayfaları.
If found to be defective as mentioned above, it will be
replaced or repaired if returned prepaid along with
proof of date of purchase. This shall constitute the sole
remedy of the purchaser and the sole liability of DynaQuip
Controls Corporation. To the extent permitted by law, the
foregoing is exclusive and in lieu of all other warranties or
System Quick Reference Setting and Status
Common Displays on WaterCopPRO Integrated
Valve is open and all components
WATERCOP
functioning.
NORMAL
Water was turned off via local controls.
WATERCOP
WATER IS OFF
Flood sensor #1 (Probe 1) detected
!ALARM!
water and turned valve off.
SENSOR #1 WET 1
#2 hardwired sensor from monitoring
!ALARM!
station detected water and turned valve
off.
WIREPANEL WET 2
Probe on Sensor #3 (probe 2) is shorted.
*** ALERT ***
Water is still on. Probe needs to be
SENSOR #3 SHT 2
checked and repaired to allow proper
function.
Probe on Sensor #2 is cut or
*** ALERT ***
disconnected. Water is still on. Probe
SENSOR #2 OPN 1
needs to be repaired or replaced to
allow proper function.
Monitoring Station has lost power or is
*** ALERT ***
out of range.
WIREPANEL LOST?
Battery in Sensor #2 is low and needs to
*** ALERT ***
be replaced.
SENSOR #2 BAT
These are the text display codes on both the WaterCopPRO
valve and monitoring station (optional).
representations whether expressed or implied, including any
implied warranty of merchantability or fitness. In no event
shall DynaQuip Controls Corporation be liable for special or
consequential damages. The WaterCopPRO brass ball valve
has a lifetime warranty.
RESET ACTUATOR TO FACTORY SETTINGS
Hold MODE, press and release OPEN– Release MODE
TO ADD DEVICES:
SENSORS:
Press MODE twice (DEVICE ADD) on WaterCopPRO
Actuator
Press CLOSE (DEVICE #1 ID)
Short probe on Sensor (SENSOR #1 SHT)
Remove Short (SENSOR #1 OK)
Press MODE
Press CLOSE (SENSOR #2 ID)
Repeat for all Sensors. When finished, Press MODE 2X
to return to NORMAL
MONITORING STATION:
Press MODE twice (DEVICE ADD) on WaterCopPRO
Actuator
Press CLOSE (DEVICE #1 ID [next device number ID]) on
WaterCop Actuator
Press CLOSE on Monitoring Station (this adds station
and also closes valve)
Press OPEN on WaterCopPRO Actuator to reopen valve
and return to NORMAL mode
REMOTE:
Press MODE twice (Device Add)
Press CLOSE (Device #1 ID)
Press CLOSE ON REMOTE (Remote #1)
TO REMOVE WIRELESS SENSORS:
Press MODE 3X (DEVICE REMOVE)
Press CLOSE to scroll to device to be removed
Press OPEN to remove that device
Press MODE to return to NORMAL
TO CHECK STATUS:
Press MODE
Scroll using CLOSE
Press MODE 3X to return to NORMAL
TO TEST SIGNAL:
HOLD MODE, press and release CLOSE
Press OPEN (TX ACTIVE SIGNAL)
Place sensor probe in water and read signal strength
When finished, Hold OPEN, press and release MODE to
return to NORMAL
4