3) Drain the ultrasonic cleaning agent. Wipe the equipment clean with a dry soft
cloth.
4) If the machine needs to be stored for a long time, discharge the testing agent
into a bottle and seal it.
4.2 Maintenance
● Replacement of testing agent After the testing agent has been used for a
period of time, a lot of impurities will accumulate, and the agent containing dirt
cannot be used, otherwise it will easily block the fuel injector. When replacing the
agent, first open the testing agent drain valve to empty the tank, and then inject a
little testing agent to clean the interior of the tank. After cleaning, drain the fuel tank
again and then pour 1L of new testing agent into the tank.
● Fuse replacement there is a square box marked with a fuse on the power
socket on the left side of the device, and the fuse can be seen by opening the box.
If it is blown, replace it with a new one.
5 Precautions
Since the test device is part of quartz glass, it is easy to break, so do not place
other objects around the equipment to avoid bumping and breaking.
● If there is no digital display after power on, please check whether the power
supply is powered; if so, check whether the plug is connected firmly, or whether the
fuse is blown. If it is not broken, and the switch is still invalid after pressing the
switch several times intermittently, please contact the manufacturer and must not
disassemble it by yourself, otherwise our company will not provide warranty.
● When no cleaning agent is added to the ultrasonic tank, it is strictly prohibited
to open the ultrasonic cleaning item to avoid damage to the ultrasonic system.
● Every time the test solution is changed, it must be cleaned up, and then 1L of
new test solution should be added.
● The use of unqualified testing agent will cause corrosion of the oil pump, oil
supply pipeline and failure of the pressure gauge.
● Using other cleaning agent and testing agent will cause the equipment surface
coating to peel off.
● It is strictly forbidden to use kerosene, gasoline or other testing agent and
cleaning agents as testing agent and cleaning agents for this machine. Otherwise,
the "O" ring and pipeline rubber parts in the equipment will be damaged, causing
leakage.
● The cleaning agent and testing agent should not be mixed up.