Dynaset HPW-DUST Kullanım Talimatları Kılavuzu - Sayfa 12
İnşaat Ekipmanları Dynaset HPW-DUST için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Dynaset HPW-DUST 20 sayfaları. High pressure dust suppression systems
12
Hydraulic high-pressure water pump HPW is recommended to install onto excavator's upper structure behind the
boom in order to easy pressure hose lying along the boom down to the nozzles. Install pump with rubber cushions
to reduce noise and vibration.
Water supply hose should be brought to the HPW-pump in the way excluding the hose to be drawn under the
crawler track of the machinery. The water supply hose must constantly be insight of an operator. Water reservoir
(if used) is recommended to lock on an excavator. Water supply hose, provided with filter, is brought in form the
upper lid or hatch.
High power dust suppression nozzles
should be fastened to a attachment
as well. Position of the nozzles
should be chosen to cover as wide
dusting area as possible. Direct
nozzles to the dust source so that
all dust are rounded by the water
mist. See picture right below.
Rotating table or foot of a attachment
is suitable for the purpose.
Nozzles should be shielded with
detachable covers against impacts.
High power dust suppression is
controlled by means of the water
solenoid
valve,
recommended to install to a basic
boom's end in suitable place to be
kept clean and intact.
2 x
High power dust suppression nozzles should be
fastened to an attachment. Position of the nozzles
should be chosen to cover as wide dusting area as
possible. Rotating table or foot of an attachment is
suitable for the purpose.
Recommended nozzles e.g. for crushing,
pulverizing or demolition:
- 2515 (48lpm 200bar 25º, Oc. 6306532000)
- 2508 (26 lpm 200 bar 25º, Oc. 6306529000)
which
is
2 x
2 x
MATERIAL FLOW
HPW-DUST HIGH PRESSURE SUPPRESSION SYSTEMS
INSTALLING COMPONENTS
4 x
NOZZLES x 4
WATER MIST
+ DUST
April 2014 JLe
HPW-PUMP
AN ALTERNATIVE:
Water reservoir
MATERIAL FLOW