Autopage RS-32 Kurulum ve Kullanım Kılavuzu - Sayfa 2
Aksesuarlar Autopage RS-32 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Autopage RS-32 2 sayfaları. Dual stage perimeter sensor
After the external field adjustment is made, adjust the interior potentiometer in
the same manner until the desired coverage is achieved. In order to isolate the
interior coverage for easy adjustment, delete the Pre-Warning of the AutoPage
alarm by pressing the arming button on the remote within five (5) seconds after
arming. If a disturbance is detected by the interior protection portion of the RS-
32, the interior LED (RED) will light and the alarm will immediately trigger. After
the interior adjustment is completed, check the exterior field again.
NOTE: If either of the LED's remains lit after installation, readjust or relocate the
sensor.
WARNING: Although the RS-32 is designed to be stable in its performance, the field disturbance sensors in general tend to have
false alarms.