c) Alkaline level preset adjustments:
i. [neutral] + [acidic], press [alkaline] or [acidic] to
ii. once the desired preset level is displayed, press
iii. use [alkaline] or [acidic] to index to desired power
13.
Trouble shooting – It is not likely that you will experience
any problems with your new Gio-Bella, but in the event you do,
refer to the chart below before calling your dealer:
SYMPTOM
Water is turned on but nothing
happens.
Filter life indicator still reads 9999
even though I changed the filter.
The ionized water has developed
a fishy or otherwise objectionable
smell or taste.
strongest acid and 1 for the weakest. Using
[alkaline] to increase and [acidic] to decrease, select
the desired value and press [neutral] + [alkaline] to
enter.
access level 1 (display 0005), level 2 (display 0006),
level 3 (display 0007), and level 4 (display 0008).
[neutral] to display current preset value of 1 to 100.
and press [neutral] + [alkaline] to enter value.
IMPORTANT – ALWAYS USE SUPPLIED TEST
KIT TO MEASURE RESULTING pH AFTER
ADJUSTING THE PRESETS.
POTENTIAL CAUSES
Diverter valve button not pulled
out.
Rear panel main power switch is
OFF.
Fuse has blown.
Circuit breaker has tripped.
Hose from diverter connected at
acid discharge instead of water
input.
Filter life counter was not reset
during filter change.
There is too high a level of
alkaline minerals.
Filter cartridge is depleted.
14
SOLUTION
Verify that water is on and that
divert button is pulled.
Verify that rear panel main power
is ON.
Verify that water hose is correctly
connected to "Water Inlet" and
secured with clamp.
Check for power at outlet by
plugging in something known to
work.
Remove fuse and verify OK
condition. Replace fuse with
250 V @1 amp if burned out.
Notify your dealer if none of the
above solves the problem.
Press and hold red filter "Reset"
button with power on until
indicator reads 9999.
Use a lower ionization level. If no
improvement, replace filter
cartridge. Replace or start using
the calcium cartridge. Check with