Autopilot APCEM2 Sorun Giderme Kılavuzu - Sayfa 6
Kontrolör Autopilot APCEM2 için çevrimiçi göz atın veya pdf Sorun Giderme Kılavuzu indirin. Autopilot APCEM2 9 sayfaları.
Troubleshooting Analog Temp Controller APCET
1. Plug controller into 120V, 60Hz power outlet. Unit should be vertical, without a heating source nearby.
2. Test photocell by covering up the PHOTOCELL with your hand or thumb (make sure to fully cover it).
After 20 seconds or so, the small LED next to "DAYTIME MODE" should turn OFF.
If DAYTIME MODE doesn't come on 30 seconds after startup, make sure it is getting plenty of light.
3. Testing Relay
While DAYTIME light is on (photocell is receiving light), and in COOL mode, turn SET DAY knob fully
counterclockwise. The OUTPUT ON light should turn on, confirm the outlet has power (plug in small
device, fan etc). Then turn SET DAY knob fully clockwise and relay should shut off power to the outlet.
4. Testing Temp Sensor
While DAYTIME light is on (photocell is receiving light), and in COOL mode, turn SET DAY knob fully
counterclockwise (same as above). The OUTPUT ON light will turn on. Slowly turn the knob clockwise
until the OUTPUT ON light turns off. Then, turn it slowly counterclockwise until OUTPUT ON light turns
on again. This temperature is the current room temperature.
NOTE: Current room temperature can be off by several degrees when comparing to another
thermometer. For increased accuracy use Digital Environmental Controller.
COOL or HEAT mode
Turn knobs, wait for 5 sec, lights will blink. Then return knob to desired set point.
COOL:
HEAT:
Error Codes:
Abnormal Temperature:
Max. Amperage Exceeded:
Red LED blinks twice every second
Red and Yellow LED blink alternately