Emerson PENBERTHY H Series Kurulum, Çalıştırma ve Bakım Talimatları - Sayfa 2
Ölçüm Cihazları Emerson PENBERTHY H Series için çevrimiçi göz atın veya pdf Kurulum, Çalıştırma ve Bakım Talimatları indirin. Emerson PENBERTHY H Series 10 sayfaları. Flat glass gages
PENBERTHY SERIES H FLAT GLASS GAGES
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
1 ABOUT THE MANUAL
This manual has been prepared as an aid and
guide for personnel involved in installation or
maintenance. All instructions must be read and
understood thoroughly before attempting any
installation, operation or maintenance.
SAFETY INSTRUCTIONS
Emerson does not have any control over the
manner in which its gage is handled, installed or
used and Emerson cannot and does not guarantee
that a gage is suitable for or compatible with the
user's specific application.
WARNING
Contained fluids may be pressurized and can
unexpectedly exit vessel connections due to
apparatus or material failure. Safety glasses
should be worn when installing a liquid level
gage. Failure to follow instructions could result
in serious physical injury.
2 INTRODUCTION
Penberthy liquid level gages are used to allow
direct visualization of liquid level in vessels.
By peering through the glass, it is possible to
monitor color, clarity and level of a gas/liquid
interface. Gages are available in varying lengths
and configurations (end connect, side connect,
multiple sections, NPT or flange connections,
etc.). Visual indication can be enhanced by
using reflex glass or illuminators (accessory).
2.1 System description
Penberthy gages comprise six basic
components. Each component may vary
slightly, depending on the desired physical and
mechanical properties for the gage. Use the
exploded parts view in Section 11 as additional
reference material.
Chamber: provides a pressure retaining
metallic channel for the liquid to enter and be
viewed. Slot(s) are machined into the chamber
to provide direct visualization of the process
fluid.
Gaskets: seal the gap and prevent leakage
between the chamber and the glass. Gaskets
are available in a variety of materials for
compatibility with the media in the gage.
Glass: allows for visual observation of the
process fluid in the chamber.
Cushion: acts as a protective buffer between
the glass and the cover. For proper sealing,
cushions must be as hard or harder than the
gasket material.
Cover: protects the glass assembly from
external hits and provides a flat, rigid surface
that is used to compress the gage assembly
evenly. The high pressure gage cover
resembles a football. It has significantly more
metal along the center of the sides to provide
more strength and resistance to high pressure
stresses.
Bolting: compresses the components between
the covers (transparent gages) or cover and
chamber (reflex gages).
Shield: (optional on transparent gages) used
to prevent the process media from contacting
the glass.
3 AVAILABLE MODELS
Penberthy high pressure (Series H) liquid level
gages are designed for applications other
than steam/water, requiring a pressure rating
higher than that of Penberthy Series L or M
liquid level gages.