DCS RGSC-305 Talimatlar Kılavuzu - Sayfa 7
Menziller DCS RGSC-305 için çevrimiçi göz atın veya pdf Talimatlar Kılavuzu indirin. DCS RGSC-305 8 sayfaları. Lp/natural conversion kit for rgsc-305 professional range
CONVERSION STICKER SAMPLES
A. From Natural Gas to LP
THIS CONVERSION RATING LABEL RELATES TO THE FOLLOWING
DCS MODELS:
RGSC305
SUPPLY PRESSURE - MINIMUM 11" W.C.
MAXIMUM 14" W.C.
MANIFOLD PRESSURE - 10" W.C.
INPUT RATINGS - FRONT & REAR BURNERS - 14,000 BTU/HR
CENTER BURNER - 14,000 BTU/HR
BAKE BURNER - 26,000 BTU/HR
BROIL BURNER - 15,000 BTU/HR
CONVERSION KIT PART. CKL-RGSC305
THIS APPLIANCE HAS BEEN CONVERTED ON
FROM NATURAL GAS TO LP GAS WITH CONVERSION KIT
PART NO. CKL-RGSC305
Name and address of qualified installer or service organization
WHO ACCEPTS RESPONSIBILTITY FOR THE CORRECTNESS OF THE
CONVERSION
B. From LP to Natural Gas
THIS CONVERSION RATING LABEL RELATES TO THE FOLLOWING
DCS MODELS:
RGSC305
SUPPLY PRESSURE - MINIMUM 6" W.C.
MAXIMUM 9" W.C.
MANIFOLD PRESSURE - 5" W.C.
INPUT RATINGS - FRONT & REAR BURNERS - 16,000 BTU/HR
CENTER BURNER - 17,500 BTU/HR
BAKE BURNER - 28,000 BTU/HR
BROIL BURNER - 15,000 BTU/HR
CONVERSION KIT PART. CKN-RGSC305
THIS APPLIANCE HAS BEEN CONVERTED ON
FROM LP GAS TO NATURAL GAS WITH CONVERSION KIT
PART NO. CKN-RGSC305
Name and address of qualified installer or service organization
WHO ACCEPTS RESPONSIBILTITY FOR THE CORRECTNESS OF THE
CONVERSION
7