This unit must be grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to
reduce the risk of electric shock.
WARNING
Refer to the drawing and parts list for the name and location of parts.
1. While opening the carton, carefully inspect outside of the carton for
any sign of transportation damage, and if so, notify your shipper
immediately.
2. Open carton and remove hoses, hose connectors and other
accessories.
3. Lay carton on its back and wheel the unit out.
4. Remove all packing, release the unit and remove Motorhead/Vacuum
Head Assembly to make sure no packing materials are left inside the
unit.
5. Check to make sure the filter is seated firmly. If not, tighten at base of
filter unit.
7. Remove the vacuum hose assembly. Note that the air supply tube (the
smaller of the two) protrudes at both ends and is longer than the
vacuum hose.
8. Connect quick coupler male end to air outlets located on vacuum
head assembly.
9. Insert vacuum hoses.
10. Connect air supply to air inlet fitting (3/8" NPT female threads)
located at the back side of Motorhead. Air pressure should be
adjusted according to the pressure requirement of the air tools you
are using. Do not exceed 150 PSIG (10.3 kg/cm
drop is unavoidable between the main air supply and the air tools due
to internal flow resistance in a long air hose.
The following items should be well-noted for the effective use of the unit.
1. Always wear safety glasses and any other safety items
required by law.
2. The vacuum system will operate by an on/auto/manual switch
located on the front of the Motorhead/Vacuum Head Assembly.
This switch must be turned on to activate the Motorhead.
3. VACUUM SPEED CONTROL: Unit is equipped with a one tool or
two tool speed setting.
4. ELECTRONIC THERMAL PROTECTION DEVICE: Unit is
equipped with a overload prevention system. If this feature is
activated a 20 MIN. COOL DOWN PERIOD inhibits use. After a
G R O U N D I N G I N S T R U C T I O N S
Grounding by means of a ground wire between both ends of the air supply tubing
passing through vacuum hose is recommended.
A S S E M B LY I N S T R U C T I O N S
2
). Some pressure
THIS IS A PRECISION PIECE OF EQUIPMENT designed for dust extraction to keep your ENVIRONMENT
and your REPUTATION "DUST-FREE." Read operating instructions before using Dynabrade Portable
Vacuum System and be thoroughly conversant with safety precautions in your locality.
O P E R AT I N G I N S T R U C T I O N S
Where it is critical to avoid shocks or sparks caused by static
electricity, an electrically conductive and grounded air supply
hose must be used.
A 1/2" INTERNAL DIAMETER SUPPLY AIR LINE is recommended.
Set regulator by installing an in-line pressure gage (Part No.
94315) at the inlet of the air tool being used. Run the tool and
adjust regulator such that there is 90 PSIG @ the tool inlet.
The installation of a Dynabrade Filter-Regulator-Lubricator (FRL
Part No. 11411) is highly recommended to protect the unit and
the air tools.
Where it is critical to avoid shocks or sparks caused by static
electricity, an air supply hose which is electrically conductive
and ground must be used.
11. All Dynabrade Vacuum Models come with a sample dust bag. Install
bag inside main body. Make sure that vacuum connection tube
protrudes through the hole in the bag.
12. Order dust bags (Part No. 96623) before you run out of them.
13. Return Motorhead/Vacuum Head Assembly to the unit and lock the
twor rim clamps to secure Motorhead/Vacuum Head Assembly in
position.
14. Connect your Dynabrade air tool or accessory and you are now ready
for working with the Dynabrade Portable Vacuum System.
complete 20 min. cool down period has passed the Electronic
Thermal Protection Device will RE-SET automatically and
the unit will be on line ready for use.
5. VISUAL WARNING SIGNAL: Unit is equipped with a visual
warning (yellow) light to indicate when air velocity falls below
20m/s. Turn off vacuum and replace disposable collection bag.
The warning signal will RE-SET automatically and the unit will