YARWAY CT150 SERIES THERMOSTATIC STEAM TRAPS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation, these instructions must be fully read and understood.
FIGURE 1
CT150 Series Thermostatic Steam Trap
WARNING
Failure to follow these instuctions or to properly
install and maintain this equipment could result in
an explosion, fire and/or chemical contamination
causing property damage and personal injury
or death.
The CT150 Series Steam Trap must be installed,
operated and maintained in accordance with
federal, state and local codes, rules and
regulations and Emerson Process Management
Regulator Technologies. Inc (Emerson)
instructions. If leaked to the unit may be required.
Failure to correct trouble could result in a
hazardous condition.
Installation, operation and maintenance
procedures performed by unqualified personnel
may result in improper adjustment and unsafe
operation. Either condition may result in
equipment damage or personal injury. Only
a qualified person shall install or service the
CT150 Series Steam Trap.
Emerson.com
INTRODUCTION
Scope of the manual
This manual provides instructions for
operation, installation and parts ordering for
the CT150 Series.
Product Description
A steam trap is an automatic valve which
discharges condensate, undesirable air and
non condensible from a system while trapping,
or holding in, steam.
Thermostatic steam traps operate in direct
response to the temperature within the trap.
The CT150 Series are thermostatically actuated
and maintenance free. Actuator is single
piece, fail open design consisting in 1.2 in.
(12.7 mm) diameter, welded 316L stainless
steel plates. Trap is constructed entirely of
316L stainless steel components with wetted
body surfaces finished to 20 μ in. Ra or better.
Trap is self draining when installed vertically
in piping systems. It has a tube or universal
ferruled connections. Ferruled connections are
Tri-clamps compatible and designed to fit both
½ and ¾ in. (12.7 and 19.1 mm) service.
© 2018 Emerson. All Rights Reserved.
SPECIFICATIONS
The specifications section gives some
general specifications for the CT150 Series
Thermostatic Steam Traps. The nameplates
give detailed information for a specific steam
trap as built in the factory.
Available Configurations
Type CT150:
Ferrule clamp end
1
in. (47.6 mm) OAL
7
/
8
Type CT150TE:
Tube end
Type CT150L:
Ferrule end
2
in. (66.7 mm) OAL
5
/
8
Body Size:
NPS ½ (DN 15)
NPS ¾ (DN 20)
NPS 1 (DN 25)
End Connection Styles:
Tube
Ferrule
Maximum Operating
Temperature
:
366°F (186°C)
(1)
Maximum Operating
Pressure
:
150 psig (10.3 bar)
(1)
Construction Materials:
316L Stainless steel
Body Surface Finish:
<20 μ in. Ra internal,
Machine Polished
external
Options:
Check valve for
Type CT150
Applications:
CIP/SIP System,
Condensate Drainage,
Sterilization of
Process, Vessels,
Culinary Steam,
Humidifiers,
WFI System
Sterilization,
Main Drips
Approximate Weights:
1.1 to 1.6 lbs
(0.5 to 0.73 kg)
FCIM-20021-EN 23/03