Specifications

LoRa Protocols: Coralink Class C, LoRaWAN Class C
LoRa Frequencies: US (915 MHz)
ETL-Listed, FCC Approved
Color: White
One Power (on/off) control button
Green status Indicator LED
USB output: 5 Volts DC, 2.4 Amps Maximum
AC Input Power: 100-120VAC, 60Hz
AC Output Rating: 100-120VAC, 15 Amps Max. (Resistive)
Environmental:
o Operating Temperature Range: 14°F – 104°F (-10°C – 40°C)
o Operating Humidity Range: < 95% non-condensing
Intended for indoor use only

Temperature Measurements and Thermal Heating

All wall sockets can experience a minor thermal heating effect localized to the socket housing
due to impedance at the socket-to-plug connection and minimal airflow inside the fixture box.
This minor heating effect is normal in the operation of all electrical sockets and is not a safety
concern. The magnitude of localized heating increases as the current draw of the connected
load increases.
The temperature sensor of the CS1030 is located inside the socket-housing. Therefore, the
temperature measurements obtained from the CS1030 should be considered a rough estimate
of ambient temperature around the unit. Especially when installed indoors, the CS1030
temperature readings may often be higher than expected due to localized thermal effects from
connected loads on either the always on-socket or the LoRaWAN controlled socket.