Replace the UV Bulbs
The Coral UV Sanitizer and Dryer comes equipped with two Philips UV-C bulbs. These bulbs should
be replaced at least once a year, however their life may be extended depending on usage. The average
lifespan of these bulbs is 6000 hours.
ATTENTION: Handle the bulbs carefully. Do not touch the glass portion of the UV bulb with bare hands. We
recommend using gloves to avoid leaving fingerprints or skin oils that affect the UV bulb. NEVER push or pull
the UV bulb from the middle.
Follow these steps to replace the UV-C bulb.
1. Unplug the product.
2. Allow bulbs time to cool down before attempting to remove.
3. Open the lid and insert the extraction tool as shown.
4. Gently pull back to release the grate, and repeat on the clip underneath.
5. Remove the protective cover, and place in a clean area.