Galvin Engineering CliniLever TM-SNKGX Kurulum Manüelleri - Sayfa 4

Sıhhi Tesisat Ürünleri Galvin Engineering CliniLever TM-SNKGX için çevrimiçi göz atın veya pdf Kurulum Manüelleri indirin. Galvin Engineering CliniLever TM-SNKGX 6 sayfaları. Stainless steel lead safe gooseneck sink mixer

Product Installation Guidelines
REMOVE & INSPECT FLOW REGULATING AERATOR
1. Remove Flow Regulating Aerator Housing
- Remove the flow regulating aerator housing as
shown.
3. Reassemble
Reverse steps 2 & 1 to reassemble ensuring the orientation is correct.
Test for leaks and correct operation.
© Galvin Engineering Pty Ltd
Flow
Regulating
Aerator
2. Remove & Inspect
Remove the flow regulating aerator.
Inspect for debris and clean. Replace if
necessary.
Version 2.1, 2 December 2021, Page 4 of 6