Product Installation Guidelines
REMOVE & INSPECT FLOW REGULATING AERATOR
1. Remove Flow Regulating Aerator Housing
- Remove the flow regulating aerator housing as
shown.
3. Reassemble
−
Reverse steps 2 & 1 to reassemble ensuring the orientation is correct.
−
Test for leaks and correct operation.
© Galvin Engineering Pty Ltd
Flow
Regulating
Aerator
2. Remove & Inspect
−
Remove the flow regulating aerator.
−
Inspect for debris and clean. Replace if
necessary.
Version 2.1, 2 December 2021, Page 4 of 6