Product Installation Guidelines
TROUBLESHOOTING
PROBLEM
Water is not flowing or
inconsistent flow.
Continous flow of
water.
Rate of flow
inadequate.
Button hard to activate.
No time flow – water
shuts off upon release.
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty
Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.
Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including but
not limited to the implied warranties of merchantability and fitness for a particular purpose.
Galvin Engineering Pty Ltd products are covered under our manufacturer's warranty available for download
from www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free
from operational defects in workmanship and materials for the warranty period as shown on the schedule in
the manufacturer's warranty. During the warranty period, Galvin Engineering will replace or repair any
defective products manufactured by Galvin Engineering without charge, so long as the terms of the
Manufacturer's warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for
breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other
property which is damaged if this product does not work properly, other costs resulting from labour charges,
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions,
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or
alteration of the product.
© Galvin Engineering Pty Ltd
CAUSE
Blocked flow restrictor/dirt in the
cartridge/water supply not on.
Top assembly cartridge loose or
internally obstructed or damaged.
The flow restrictor may not be
satisfactory due to inadequate supply
pressure.
Mains pressure may be too high.
Small spring at the bottom of the
cartridge piston dislodged.
Version 1.1, 13 May 2021, Page 4 of 4
RECTIFICATION
Remove flow regulator from the inlet and
remove debris. Install an inline strainer to
stop further blockages. Ensure water
supply is turned on.
Remove cartridge, clean with water and
re-grease spindle if required.
Remove flow restrictor and replace with a
flow restrictor of different capacity to suit
(available from Galvin Specialised).
Reduce mains pressure to below 500kPa
(70 PSI).
Relocate spring, regrease spindle if
required.