6. Tubing connection
Connect the tubing between the
water flow outlet and the hose
barb inlet.
It is recommended that a prefilter
be used with the Turbo-Twist to
limit the amount of debris entering
the sterilizer.
Warning:
Never install
a valve on the
tubing between
the main body
and the
aquarium.
Note: Make sure that the tubing is not carrying the weight
of the Turbo-Twist UV Sterilizer. Use the Turbo-Twist brackets
to support the unit to a firm surface.
7. Start water flow
Turn on water supply to the Turbo-Twist. Once proper water flow has been established, tilt the unit and let
the air bubbles inside the tubing and the main body escape. Examine the unit and check for any leaks.
8. Power up Turbo-Twist
Connect the Turbo-Twist to the power supply. Verify that the UVC
lamp is working properly, indicated by the light blue glow emitted
through the lamp-on indicator. The light from the lamp-on
indicator will not affect the skin or the eye.
• Never look directly at the unshielded lamp as ultraviolet
radiation is harmful.
• Disconnect the UV Sterilizer from the power supply when
installing or performing maintenance.
• Never submerse the UV Sterilizer in water.