Galvin Specialised 368667X Ürün Kurulum Manualline - Sayfa 2

Sıhhi Tesisat Ürünleri Galvin Specialised 368667X için çevrimiçi göz atın veya pdf Ürün Kurulum Manualline indirin. Galvin Specialised 368667X 4 sayfaları. Lead safe timeflow push button bib tap – 6 sec

PRE-INSTALLATION
MOUNTING DETAILS
Note: Before installation, all lines must be flushed. We recommend that a line strainer be installed prior to
Ezy-Push Time Flow Bib taps to eliminate any foreign material
INSTALLATION
IMPORTANT: Galvin Engineering products must be installed in accordance with these installation instructions
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical
supply conditions must also comply to the applicable national and/or state standards. Failing to comply with
these provisions shall void the product warranty and may affect the performance of the product.
1. Fit tap assembly
Time flow taps are fitted with flow
restrictors.
When applying thread tape or sealant to
the inlet, ensure the opening is not
obscured. Failure to do so may restrict
or block the flow restrictor, affecting the
flow of water.
Version 3,15
.
Flow Regulator
2. Replacing flow restrictor (if required) and fitting
water temperature indicator
Major restrictions to the supply pressure may
effect the water stream and the flow restrictor
may need replacing with a flow restrictor of
greater capacity to increse the flow. However,
using a different flow restrictor will void the 6
star rating.
Never operate without a flow restrictor, as Ezy-
®
Push
Time Flow Deluxe Bib taps will deliver
full mains pressure with unrestricted flow.
Fit the appropriate water temperature
indicator (Cold, Hot or Warm).
th
July 2020,
Page 2 of 4