AGS Merlin 1000S+ Kurulum Operasyon ve Bakım - Sayfa 4
Gaz Dedektörleri AGS Merlin 1000S+ için çevrimiçi göz atın veya pdf Kurulum Operasyon ve Bakım indirin. AGS Merlin 1000S+ 12 sayfaları. Gas and electric isolation controller
Ayrıca AGS Merlin 1000S+ için: Kullanıcı Kılavuzu (12 sayfalar)
Installation & Operation Manual
Installation
Typical Application & Location
Installation must be carried out by a licenced, insured contractor!
Installation must be in accordance with recognised standards in the country concerned, for North America, NEC / CEC
regulations should be followed!
Cables must be protected against mechanical damage!
The 1000S+ panel is a gas pressure proving and electric isolation system is designed specifically for
use in educational establishments and laboratories.
The panel is designed to give the teacher full control over the incoming gas supply & bench electrics
with the lockable main key-switch and touch sensors.
The panel can work in conjunction with carbon dioxide, natural gas, carbon monoxide and LPG
sensors. It also has a built in "timeout" facility which will automatically shut off the gas solenoid valve
at the end of a specific time, this time can be adjusted to 2, 5, 8 hours or can be overridden if
required.
Mounting & Cabling
If mounting direct to wall - ensure the wall surface is flat to prevent base distortion!
Ensure the rear base is installed in the correct orientation as shown!
Where cable glands/conduits are used for wire entry, use 20mm (3/4 inch) max separated by at least 20mm!
Any parts that form part of the connections/installation must have a minimum fire-retardant rating of UL94v-2!
Damage to PCBs when creating cable entry points or attempting to remove the circuit board may void any warranty!
Restrain the hazardous live wiring from accidental loosening to prevent wires from moving after installation and touching
parts of opposite polarity or at low voltages!
Isolate the equipment from all hazardous live power sources before opening the cover!
Place the panel 48-60 inches above finished floor level.
Designed for surface mounting, it must be installed by a licensed,
insured contractor.
Carefully remove the front cover from the unit by unscrewing the
1.
four bolts located at each corner. To do this – use the socket wrench provided.
Remove the keys and spare parts - keep safe.
2.
Mark the four screw holes located on the back of the enclosure to the wall. Ensure the wall surface is flat
3.
to prevent base distortion. Drill out as necessary ensuring all swarf is removed from the box and holes
have smooth edges.
After executing the mounting and the connections –replace the front cover and insert the security caps
4.
over the four bolts.
A flush mount kit is available, comprising of a mounting bracket and decorative surround strip.
Contact your supplier for more information.
Rev: 13
08-22
Merlin 1000S+
4