NONEL
Application Recommendations
ALWAYS
use the plastic J-Hook when using a detonating cord trunkline to tie-in
NONEL LP nonelectric delay detonators. A minimum 3.6 g/m (18 gr/ft) detonating
cord trunkline is required for use with the J-Hook.
ALWAYS
ensure the shock tube is connected at right angles to the detonating
cord trunkline and that the shock tube leads returning to the hole collar do not
cross over or lay near any detonating cord trunkline. If the detonating cord
touches the shock tube or is closer than 15 cm (6 inches), the shock tube may be
damaged and misfires may result.
ALWAYS
connect detonating cord using approved knots and tight connections.
Place detonating cord hook-ups in closed loops and use with cross-ties.
NEVER
cut or trim seals from the shock tube of a NONEL LP delay. If shock
tubing is cut or is suspected of being cut or damaged during loading,
reprime the blast-hole using a new unit of the same delay period.
NEVER
drive any equipment over shock tube or detonating cord. Whenever
charging from a manoeuvrable basket, platform or boom,
that no shock tube or detonating cord is entangled or can become entangled.
ALWAYS
make sure that no shock tube or detonating cord can be pinched
between the basket, platform or boom and the face, ribs, back or floor. Rupturing
or damaging shock tube or detonating cord may cause misfires.
Dyno Nobel Asia Pacific Pty Limited (ACN 003 269 010) is a subsidiary of
Version 10
Incitec Pivot Limited (ACN 004 080 264) Level 8, 28 Freshwater Place, Southbank Vic 3006
February 2018
Phone 1800 251 872 www.dynonobel.com
LP Series
ALWAYS
make sure
Application Recommendations (continued)
Sleep Time - The sleep time of the NONEL LP Series is dependent on the
temperature and type of explosive in contact with the unit. Please contact Dyno
Nobel for further information.
Water Resistance - The NONEL LP Series provides excellent water resistance.
Ground Temperature - The NONEL LP Series can be safely used in ground with
a temperature range of -40°C to +70°C.
Shelf Life - For maximum shelf life (3 years), NONEL LP units must be stored in
a cool, dry, well ventilated magazine. Explosive inventory should be rotated. Avoid
using new materials before old stocks have been depleted.
Packaging
ALWAYS
Length (m)
3.6
4.8
5.4
6.0
7.2
15
Technical
Information
Case Count
Configuration
250
Coil
200
Coil
180
Sidewinder
150
Coil
150
Coil
75
Figure 80