HIKOKI DH18DSL Taşıma Talimatları Kılavuzu - Sayfa 7
Döner Çekiç HIKOKI DH18DSL için çevrimiçi göz atın veya pdf Taşıma Talimatları Kılavuzu indirin. HIKOKI DH18DSL 16 sayfaları. Cordless rotary hammer
Before
charging
While
charging
Charge
indicator
lamp
(red / blue /
Charging
green /
complete
purple)
Overheat
standby
Charging
impossible
NOTE: When standby for cooling battery, UC18YSL3 cools the overheated battery by cooling fan.
● Regarding the temperatures and charging time of the battery
The temperatures and charging time will become as shown in Table 2.
Battery
Charging voltage
Weight
Temperatures at which the battery can be
recharged
Charging time for battery capacity, approx.
(At 20oC)
1.3 Ah
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
6.0 Ah
Number of battery cells
*1 AC power supply / DC 12V (in-car) power supply
NOTE
The recharging time may vary according to the ambient
temperature and power source voltage.
<UC18YML2>
Especially, using a DC 12V in-car power source may
require longer recharging time at high temperatures.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger's power cord from the
receptacle or cigarette lighter socket.
5. Hold the charger fi rmly and pull out the battery.
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light for
Blinks
0.5 seconds. (off for 0.5 seconds)
(red)
Lights for 0.5 seconds. Does not light for
Blinks
1 second. (off for 1 second)
(blue)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(blue)
Lights
Lights continuously
(blue)
Lights continuously
Lights
(green)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light for
Blinks
0.3 seconds. (off for 0.3 seconds)
(red)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Flickers
(purple)
(Intermittent buzzer sound: about
2 seconds)
Charger
V
kg
min.
min.
min.
min.
min.
min.
min.
min.
Table 1-b
Table 2
UC18YFSL
0.5
0oC – 50oC
20
22
30
35
45
60
75
90
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
CAUTION
○ If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of UC18YML2 charger lights up green, or the
pilot lamp of UC18YFSL charger lights for 1 second,
does not light for 0.5 seconds (off for 0.5 seconds), or
the charge indicator lamp of UC18YSL3 charger lights
for 0.3 seconds, does not light for 0.3 seconds (off for
0.3 seconds). In such a case, fi rst let the battery cool,
then start charging.
7
Plugged into power source
Battery capacity at less than 50%
Battery capacity at less than 80%
Battery capacity at more than 80%
Battery overheated. Unable to
charge. (Charging will commence
when battery cools)
Malfunction in the battery or the
charger
UC18YML2
(AC/DC)*
1
14.4V – 18V
0.7
20 / 50
22 / 60
30 / 80
35 / 100
45 / 120
60 / 160
75 / 200
90 / 240
4 – 10
UC18YSL3
0.6
-10oC – 50oC
15
15
20
25
20
26
32
38