HIKOKI UC 36YRSL Taşıma Talimatları Kılavuzu - Sayfa 15

Akü Şarj Cihazı HIKOKI UC 36YRSL için çevrimiçi göz atın veya pdf Taşıma Talimatları Kılavuzu indirin. HIKOKI UC 36YRSL 20 sayfaları.

NOTE
When standby for cooling battery, UC36YRSL cools the overheated battery by cooling fan.
(2)
Regarding the temperature of the battery.
The temperatures for batteries are as shown in the Table 2, and batteries that have
become hot should be cooled for a while before being recharged.
Batteries
BSL1415, BSL1415X, BSL1420, BSL1430, BSL1440,
BSL1815, BSL1815X, BSL1820, BSL1830, BSL1840,
BSL2530, BSL3620, BSL3626
(3)
Regarding recharging time
Table 3 shows the recharging time required according to the type of battery.
Table 3 Recharging time (approx.) at 20°C
Battery
Voltage
14.4 V
18 V
25.2 V
36 V
NOTE
The recharging time may vary according to the ambient temperature.
4.
Disconnect the charger's power cord from the receptacle.
5.
Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use, and then keep it.
How to make the batteries perform longer.
(1)
Recharge the batteries before they become completely exhausted.
When you feel that the power of the tool becomes weaker, stop using the tool and recharge
its battery. If you continue to use the tool and exhaust the electric current, the battery may
be damaged and its life will become shorter.
(2)
Avoid recharging at high temperatures.
A battery will be hot immediately after use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate, and the battery life will be shortened.
Leave the battery and recharge it after it has cooled for a while.
1.5 Ah
2.0 Ah
30 min.
40 min.
30 min.
40 min.
60 min.
Table 2
Temperature which the battery
Battery capacity (Ah)
Li-ion Battery
2.6 Ah
80 min.
15
English
can be recharged
0°C – 50°C
3.0 Ah
4.0 Ah
60 min.
80 min.
60 min.
80 min.
60 min.